Key result
A novel low-power sensor measuring upper thoracic electrostatic charge variation consumed only 87.3 µW of power, showing an order of magnitude power savings compared with photoplethysmography sensors.
Why the study?
Continuous cardiac monitoring solutions can monitor patient status and detect early warning signs, but energy-efficient and long-lasting wearable devices are needed.
A novel low-power sensor for cardiac monitoring demonstrates significant energy savings compared to existing technologies while maintaining accurate QRS detection.
Answers are grounded in this paper and cite their sources.
May enable prolonged wearable cardiac monitoring on coin-cell batteries; leaves open prospective validation before clinical adoption.
Cardiovascular disease is a major cause of premature mortality, high healthcare costs, and disability-adjusted life years. Digital interventions such as continuous cardiac monitoring solutions can help to monitor the patient status and provide valuable feedback to clinicians to detect early warning signs and provide effective interventions. This paper presents the evaluation of a novel low-power sensor exploited to measure the electrostatic charge variation in the upper thorax to provide an energy-efficient and accurate detection of the electric activity of the heart. The sensor is investigated for measuring the heart activity in terms of the QRS complex. The paper presents the design of a wearable sensor device, optimization of electrode positions and incorporation into a wearable chest strap that can be integrated seamlessly under clothes. Due to the low power consumption of the sensor, the sensor node consumes only 87.3 µW of power and can provide multiple weeks of operation using a coin cell battery while providing the same functionality as that of commercially available sensors such as photoplethysmography and electrocardiogram (ECG) ICs. In addition, the chest strap was also characterised for different use scenarios during sedentary and activity periods. We evaluated both the signal quality and the power consumption compared with other sensors technology showing a power save of an order of magnitude when compared with photoplethysmography sensors.
No takes yet. Share an insight, caveat, or question.
Dheman et al. (2022) studied Cardiac monitoring. Novel low-power sensor measuring upper thoracic electrostatic charge variation vs. Photoplethysmography and electrocardiogram (ECG) ICs was evaluated on Power consumption and signal quality. A novel low-power sensor measuring upper thoracic electrostatic charge variation consumed only 87.3 µW of power, showing an order of magnitude power savings compared with photoplethysmography sensors.