This article focuses on providing the laminated busbar design guidance for a three-level T-type neutral-pointclamped (3L-TNPC) inverter to achieve low stray inductance and balanced inductance distribution between paralleled power switches. As a result, equalized dynamic current sharing can be accomplished. To discover the design strategy, this article first derives the mutual-inductance-decoupled equivalent circuit for 3L-TNPC. Then, the effects of each inductance item on switching performance can be unveiled, and the parametric targets are then summarized. Accordingly, the busbar design considerations are discussed. A step-by-step busbar design procedure to achieve the aforementioned design targets is provided in the next. The design procedure starts from 2-D optimization to achieve the optimal component and terminal allocation, and then, it increases the optimization degree to 3-D. Using this design procedure, we proposed a novel double-side-end busbar structure to achieve the busbar stray inductance of 12.7 nH and the inductance differences between the paralleled switches to be less than 2 nH. Extensive experiments are carried out in the end to evaluate the design procedure and demonstrate the performance of the busbar.
No takes yet. Share an insight, caveat, or question.
Yuan et al. (2019) studied this question.