Key result
In dogs under general anesthesia, there was a significant but negligible negative correlation between the ratio of short diameter of the caudal vena cava to aortic diameter of the thorax and mean blood pressure (r = -0.289, p = 0.003).
Why the study?
This study investigated the association between caudal vena cava size and circulatory dynamics in dogs using computed tomography under general anesthesia.
What factors influence caudal vena cava size assessed by CT in dogs under general anesthesia?
Cross-Sectional (n=104)
Single-blind
No
What factors influence caudal vena cava size assessed by CT in dogs under general anesthesia?
Effect estimate: r = -0.289
p-value: p=0.003
Caudal vena cava size assessment using CT in dogs under general anesthesia is significantly influenced by factors such as blood pressure, cardiac disease, intra-abdominal mass, and anemia.
This study investigated the association between caudal vena cava (CVC) size and circulatory dynamics in dogs using computed tomography (CT) under general anesthesia. The subjects were 104 dogs who had undergone CT under general anesthesia in the past. The ratio of short diameter of the CVC to aortic diameter (CVCS/Ao) and the ratio of long to short diameter of the CVC (CVCL/CVCS) in the thorax and abdomen, respectively, were calculated using factors such as mean blood pressure (MBP), shock index (SI), anemia, hypoproteinemia, presence of intra-abdominal mass, and cardiac disease. There was a significant but negligible negative correlation between CVCS/Ao and MBP. In contrast, no significant correlation was found between CVC size and SI. The low MBP group had significantly higher CVCS/Ao of the thorax than the normal MBP group. The group with intra-abdominal mass had significantly lower CVCS/Ao of the abdomen than the group without intra-abdominal mass. The group with cardiac disease had significantly lower CVCL/CVCS of the thorax than the group without cardiac disease. In multiple regression analysis, low MBP, cardiac disease, intra-abdominal mass, and anemia were significant factors for CVCS/Ao of the thorax, CVCL/CVCS of the thorax, CVCS/Ao of the abdomen, and CVCL/CVCS of the abdomen, respectively. In conclusion, CVC size assessment using CT in dogs under general anesthesia is influenced by various factors.
No takes yet. Share an insight, caveat, or question.
Hanazono et al. (2022) conducted a cross-sectional in Dogs under general anesthesia (n=104). Mean blood pressure (MBP) was evaluated on Correlation between the ratio of short diameter of the caudal vena cava to aortic diameter (CVCS/Ao) of the thorax and mean blood pressure (r = -0.289, p=0.003). In dogs under general anesthesia, there was a significant but negligible negative correlation between the ratio of short diameter of the caudal vena cava to aortic diameter of the thorax and mean blood pressure (r = -0.289, p = 0.003).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: