Answers are grounded in this paper and cite their sources.
Diagnostic accuracy of CECT for solid organ injuries in blunt trauma patients, highlighting key findings.
Objective: To determine the diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of Contrast-enhanced computed tomography (CECT) in detecting intra-abdominal solid organ injuries in blunt abdominal trauma patients, using laparotomy findings as the gold standard.Methods: This diagnostic accuracy cross-sectional study was performed at the Department of Diagnostic Radiology, Combined Military Hospital, Multan in the time span of six months after getting ethical approval.Total 174 patients with blunt abdominal trauma were enrolled in this diagnostic accuracy cross sectional study. All patients underwent CECT followed by exploratory laparotomy. Participants were male or female adults aged between 20 and 60 years. Data was analysed using SPSS version25. Findings of CECT were compared with operative findings of laparotomy. Diagnostic indicators such as sensitivity, specificity, PPV, NPV, and diagnostic accuracy were estimated using 2 × 2 contingency tables. Sub-group analysis was carried out to assess influence of time elapsed from injury to CECT scanning and degree of organ damage on diagnostic performance.Results: The overall sensitivity of CECT for solid organ injury detection was 90.14% (95% CI: 84.1–94.0), whereas specificity was 96.88% (95% CI: 84.3–99.5). The sensitivity and specificity for the detection of liver injury were 92.59% (95% CI: 82.9–97.2) and 98.33% (95% CI: 94.1–99.6), respectively. For splenic injuries, the sensitivity and specificity values were 92.65% (95% CI: 84.0–97.0) and 98.11% (95% CI: 93.4–99.5), respectively. In renal injuries, sensitivity of CECT findings was lower at 84.38% (95% CI: 68.2–93.1) but still had excellent specificity at 98.59% (95% CI: 95.0–99.6). Pancreatic injuries had lowest sensitivity at 66.67% (95% CI: 43.7–83.7), although specificity remained high at 98.71% (95% CI: 95.4–99.7).Conclusion: CECT is one of the most accurate and specific imaging techniques for evaluation of liver, spleen, and kidney injuries in patients with blunt trauma to abdomen. Nevertheless, the low sensitivity to pancreatic trauma underlines the importance of meticulous clinical examination, and at times, supplementary diagnostic tests
No takes yet. Share an insight, caveat, or question.
Maryam et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: