Answers are grounded in this paper and cite their sources.
Systematic review assesses mechanical failures and complications of 3IPP, indicating significant concerns for patients.
Introduction Three-piece inflatable penile prosthesis (3IPP) implantation is a cornerstone in the management of chronic organic erectile dysfunction, providing the most natural patient experience. However, substantial concerns persist regarding 3IPP long-term device survival, mechanical failure rates, and complication prevalence. Objective Most available studies are not focused specifically on 3IPP, include low-volume samples or cohorts with relatively short follow-up, yielding potentially incomplete picture with likely underestimation of problem numbers. Methods In this study, we combined a systematic review of 3IPP survival, mechanical failures, and complication rates with a series of meta-analyses limited to high-volume studies (n≥200) with a mean follow-up of ≥1 year. Results Pooled estimates of overall device survival rate demonstrated a progressive decline over time. At one year post-implantation, the estimated survival rate was 94.3% (95% confidence intervals, CI 92.7–95.5%), gradually decreasing to 90.7% (CI 88.3–92.7%), 86.3% (CI 82.7–89.2%), and 72.3% (CI 68.0–76.3%) at 3, 5, and 10 years, respectively. 3IPP could have a number of mechanical failures, such as leakage in various sites, pump malfunction, and inflation/deflation difficulties. A pooled prevalence of mechanical failures accounted for 4.7% (CI 2.8–7.7%) in studies with less than 3 years of follow-up, rising to 9.4% (95% CI 6.3–13.8%) in studies with 3 or more years of follow-up. For device infections, a pooled estimate rate was 2.2% (CI 1.5–3.1%). Surgical complications encompassed hematoma (pooled prevalence 2.0%, CI 0.9-4.3%), cylinder malposition and other cylinder-related issues (0.9%, CI 0.3-2.5%), various erosions (1.0%, CI 0.5-1.9), reservoir-related complications (0.4%, CI 0.2-0.9%), and a wide range of less common issues such as intraoperative injuries and chronic pain. Conclusions Despite some advances in device design and surgical technique, complications and mechanical failures lead to a considerable decline in 3IPP survival over the first 3–10 years. These findings highlight multiple areas for improvement in 3IPP treatment, including the development of next-generation penile prosthetic devices and optimization of peri-, intra-, and postoperative strategies. Disclosure No
No takes yet. Share an insight, caveat, or question.
Sforza et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: