Key result
Point-of-care testing using a dual- or triple-marker panel showed high sensitivity and specificity for diagnosing AMI, with results available in 26 minutes vs 65 minutes.
Why the study?
Does point-of-care testing with a multi-marker panel provide comparable diagnostic precision to standard laboratory testing in patients with suspected AMI and non-diagnostic ECGs?
Observational (n=51)
Does point-of-care testing with a multi-marker panel provide comparable diagnostic precision to standard laboratory testing in patients with suspected AMI and non-diagnostic ECGs?
Point-of-care testing with a multi-marker panel offers comparable diagnostic precision to standard laboratory testing for AMI, but with significantly faster turnaround times.
Answers are grounded in this paper and cite their sources.
May support faster AMI diagnosis with POC panels in non-diagnostic ECGs; hypothesis-generating, needs prospective validation before practice change.
INTRODUCTION: Up to 40% of patients with acute myocardial infarction (AMI) present with non-diagnostic electrocardiograms (ECGs). The diagnosis in such cases is usually made with the aid of biochemical markers. Newer and more rapid assays for such markers have now enabled testing to be done on-site instead of in the laboratory. This potentially enables the clinician to rapidly diagnose and triage patients. We evaluated the diagnostic precision of this point-of-care testing strategy using one such analyser, the Stratus CS (Dade Behring) in a prospective study. MATERIALS AND METHODS: The study population consisted of 51 consecutive patients admitted for suspected AMI with non-diagnostic ECGs. Two blood samples from each patient were drawn simultaneously on admission. The first sample was assayed for myoglobin, troponin I (TnI) and creatine kinase-MB (CKMB) mass by the point-of-care instrument (Stratus CS), and the second sample was sent for standard testing for AMI, comprising a troponin-T (TnT) qualitative test and the analysis of CKMB by the hospital laboratory. Utilising the recommended cut-off values for the individual assays, the results of these 2 sets of tests were evaluated based on whether they were positive or negative for AMI and compared against the patient's final diagnosis at discharge. Various combinations of markers were assessed. RESULTS: On evaluation of individual markers, myoglobin was the most sensitive (75%) at 0 to 6 hours after onset of symptoms, while TnI (95%), TnT (80%) and CKMB-mass (90%) performed better at 7 to 12 hours. Point-of-care testing utilising a combination of markers was highly sensitive and specific. Both dual-marker panels of myoglobin with TnI and myoglobin with CKMB-mass yielded equivalent overall sensitivities and specificities of 90% and 95% respectively. A triple-marker panel of myoglobin, TnI and CKMB-mass had a sensitivity of 93% and specificity of 95%. All point-of-care testing panels had good positive and negative predictive values, and showed comparable diagnostic efficacy with the standard testing presently utilised for the diagnosis of AMI. The average time for results to become available was up to 26 minutes for point-of-care testing and 65 minutes for standard testing. CONCLUSION: Point-of-care testing utilising a panel of 2 or 3 cardiac markers has comparable diagnostic precision to the presently utilised testing strategy for AMI, with earlier availability of results.
No takes yet. Share an insight, caveat, or question.
Hsu et al. (2000) conducted an observational in Suspected acute myocardial infarction with non-diagnostic ECGs (n=51). Point-of-care testing (Stratus CS) for cardiac markers vs. Standard laboratory testing was evaluated on Diagnostic precision (sensitivity and specificity) for acute myocardial infarction. Point-of-care testing using a dual- or triple-marker panel showed high sensitivity and specificity for diagnosing AMI, with results available in 26 minutes vs 65 minutes.
Synapse has enriched 10 related papers. Consider them for comparative context: