Key result
Adjunctive PLAA linked to lower healthcare utilization versus PVI alone for first-time AF ablation.
Why the study?
Limited real-world efficacy and safety data are available for adjunctive posterior left atrial ablation using pulsed field ablation technology despite its rapid adoption into practice.
Does adjunctive posterior left atrial ablation added to pulmonary vein isolation using pulsed field ablation reduce healthcare utilization compared to pulmonary vein isolation alone in patients undergoing first-time catheter ablation for atrial fibrillation?
Cohort (n=1,611)
Yes
Does adjunctive posterior left atrial ablation added to pulmonary vein isolation using pulsed field ablation reduce healthcare utilization compared to pulmonary vein isolation alone in patients undergoing first-time catheter ablation for atrial fibrillation?
In a large multicentre real-world registry of first-time pulsed field ablation for atrial fibrillation, adding posterior left atrial ablation to PVI was associated with reduced healthcare utilization and arrhythmia recurrence without increasing 30-day adverse events.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for lower utilization with adjunctive PLAA; randomized trials needed before practice change.
BACKGROUND Limited data are available on the real-world efficacy and safety of adjunctive posterior left atrial ablation (PLAA) using pulsed field ablation (PFA) technology despite its rapid adoption into practice. OBJECTIVES The study compares the efficacy and safety of pulmonary vein isolation (PVI)+PLAA vs PVI alone using PFA. METHODS Retrospective analysis of patients who underwent first-time ablation with Farapulse PFA system using data collected in the Australia and New Zealand Pentaspline PFA registry. Primary outcome was healthcare utilization (composite of unplanned rehospitalization for atrial arrhythmias, cardioversion, and/or repeat ablation). RESULTS Of the 1611 patients undergoing ablation, adjunctive PLAA was performed in 30%. Compared to PVI alone, patients receiving PVI+PLAA were older with higher CHA2DS2-VA score, and more likely to have non-paroxysmal AF (74% vs 27%), LA dilatation, and reduced LVEF (p<0.01 for all comparisons). There was no significant difference in 30-day adverse events (0.8% vs 0.5%, p=0.50). After adjustment for baseline differences, healthcare utilization was reduced in patients undergoing PVI+PLAA with an adjusted HR of 0.52 (95%CI 0.31-0.89; p=0.016) during median follow-up of 426 days. The adjusted risk of unplanned rehospitalization, cardioversion, and clinical arrhythmia recurrence was all significantly lower for PVI+PLAA (p<0.05). Following propensity score matching, PVI+PLAA was also associated with lower risk of healthcare utilization (HR 0.57; 95%CI 0.34-0.96; p=0.03). CONCLUSIONS In the largest multicentre comparative analysis of adjunctive PLAA+PVI vs PVI alone using PFA to date, adjunctive PLAA ablation was safe and was associated with lower healthcare utilization in patients undergoing first-time catheter ablation for AF.
No takes yet. Share an insight, caveat, or question.
Sindone et al. (2026) conducted a cohort in Atrial fibrillation (n=1,611). Pulmonary vein isolation plus adjunctive posterior left atrial ablation (PVI+PLAA) using pulsed field ablation vs. Pulmonary vein isolation (PVI) alone using pulsed field ablation was evaluated on Healthcare utilization (composite of unplanned rehospitalization for atrial arrhythmias, cardioversion, and/or repeat ablation) (HR 0.52, 95% CI 0.31-0.89, p=0.016). Adjunctive posterior left atrial ablation plus PVI using pulsed field ablation reduced healthcare utilization vs PVI alone.
Synapse has enriched 10 related papers. Consider them for comparative context: