Key result
Transoesophageal echocardiography under general anaesthesia yielded lower left ventricular dimensions but similar global systolic function compared to published normal values in awake subjects.
Why the study?
What are the reference values for left ventricular dimensions and systolic function assessed by TEE in patients under general anaesthesia compared to awake subjects?
Observational (n=45)
What are the reference values for left ventricular dimensions and systolic function assessed by TEE in patients under general anaesthesia compared to awake subjects?
This study establishes specific reference values for left ventricular dimensions and function using TEE in patients under general anaesthesia, noting that dimensions are smaller than in awake patients while global systolic function remains similar.
Answers are grounded in this paper and cite their sources.
Supports GA-specific TEE LV dimension references; hypothesis-generating and should not yet change practice.
BACKGROUND AND OBJECTIVE: Transoesophageal echocardiography is increasingly used for evaluation and monitoring of left ventricular function in anaesthetized patients. However, the only available reference values for transoesophageal echocardiography were derived from studies in awake subjects. METHODS: We determined left ventricular dimensions and systolic function in 45 patients without clinical evidence of heart disease who voluntarily underwent transesophageal echocardiography under conditions of balanced general anaesthesia, controlled fluid administration, supine position, muscle relaxation and controlled ventilation. RESULTS: The left ventricular dimensions obtained during these conditions were lower than the published normal values in awake subjects. The indices of global left ventricular function, however, were similar to the normal values obtained by either awake transesophageal echocardiography or transthoracic echocardiography. CONCLUSION: We propose using the values obtained in our study as reference values for evaluation of left ventricular function in patients under general anaesthesia and controlled ventilation.
No takes yet. Share an insight, caveat, or question.
Skarvan et al. (2001) conducted an observational in Without clinical evidence of heart disease (n=45). Transoesophageal echocardiography under general anaesthesia vs. Awake subjects (published normal values) was evaluated on Left ventricular dimensions and systolic function. Transoesophageal echocardiography under general anaesthesia yielded lower left ventricular dimensions but similar global systolic function compared to published normal values in awake subjects.
Synapse has enriched 10 related papers. Consider them for comparative context: