Key result
Cryoballoon ablation is a feasible alternative to radiofrequency catheter for pulmonary vein isolation in patients with pre-existing Watchman devices.
Why the study?
Is cryoballoon pulmonary vein isolation feasible in patients with symptomatic atrial fibrillation and a pre-existing Watchman device?
Case Report
Is cryoballoon pulmonary vein isolation feasible in patients with symptomatic atrial fibrillation and a pre-existing Watchman device?
Cryoballoon ablation is feasible for PVI in patients with a Watchman device, though timing must account for device endocardialization to minimize thrombus risk.
Answers are grounded in this paper and cite their sources.
Supports cryoballoon PVI feasibility with Watchman devices; hypothesis-generating and requires prospective validation before wider use.
Key Teaching Points•Cryoballoon ablation is a feasible alternative to radiofrequency catheter for pulmonary vein isolation (PVI) ablation in patients with pre-existing Watchman devices.•Caution should be taken with regard to the timing of PVI post-Watchman implantation owing to interpatient variability in time to endocardialization of the device surface and potential risk of ablation-related thrombus formation.•Three-dimensional electroanatomic mapping provides enhanced knowledge of left atrial anatomy and assists in locating pulmonary veins prior to cryoballoon deployment.•High-amplitude left atrial appendage–like electrograms may be observed on the surface of endocardialized Watchman devices. •Cryoballoon ablation is a feasible alternative to radiofrequency catheter for pulmonary vein isolation (PVI) ablation in patients with pre-existing Watchman devices.•Caution should be taken with regard to the timing of PVI post-Watchman implantation owing to interpatient variability in time to endocardialization of the device surface and potential risk of ablation-related thrombus formation.•Three-dimensional electroanatomic mapping provides enhanced knowledge of left atrial anatomy and assists in locating pulmonary veins prior to cryoballoon deployment.•High-amplitude left atrial appendage–like electrograms may be observed on the surface of endocardialized Watchman devices.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2017) conducted a case report in Symptomatic atrial fibrillation. Cryoballoon pulmonary vein isolation and voltage mapping was evaluated. Cryoballoon ablation is a feasible alternative to radiofrequency catheter for pulmonary vein isolation in patients with pre-existing Watchman devices.
Synapse has enriched 10 related papers. Consider them for comparative context: