Key result
The deep recurrent neural network ArNet estimated atrial fibrillation burden with a median absolute error of 1.2%, outperforming the gradient boosting model's error of 3.1%.
Why the study?
Atrial fibrillation burden has shown added prognostic value over binary diagnosis, motivating evaluation of deep recurrent neural networks to estimate it over continuous recordings.
Does a deep recurrent neural network (ArNet) improve the estimation of atrial fibrillation burden from 24h beat-to-beat interval time series compared to a gradient boosting model?
Observational (n=2,891)
No
Does a deep recurrent neural network (ArNet) improve the estimation of atrial fibrillation burden from 24h beat-to-beat interval time series compared to a gradient boosting model?
A deep recurrent neural network accurately estimates atrial fibrillation burden from 24-hour beat-to-beat interval time series, outperforming traditional feature-engineering machine learning models.
Answers are grounded in this paper and cite their sources.
Facilitates precise AF burden tracking from ambulatory ECG; leaves open prospective validation before clinical adoption.
Objective: The atrial fibrillation burden (AFB) is defined as the percentage of time spent in atrial fibrillation (AF) over a long enough monitoring period. Recent research has suggested the added prognostic value of using the AFB compared to a binary diagnosis. We evaluate, for the first time, the ability to estimate the AFB over long-term continuous recordings, using a deep recurrent neutral network (DRNN) approach. Methods: The models were developed and evaluated on a large database of p = 2,891 patients, totaling t = 68,800 hours of continuous electrocardiography (ECG) recordings from the University of Virginia. Specifically, 24h beat-to-beat time series were obtained from a single portable ECG channel. The network, denoted ArNet, was benchmarked against a gradient boosting (XGB) model, trained on 21 features including the coefficient of sample entropy (CosEn) and AFEvidence that is derived from the number of irregular points revealed by the Lorenz plot. The generalizations of ArNet and XGB were also evaluated on the independent PhysioNet LTAF test database. Results: the absolute AF burden estimation error | E AF (% ) |, median and interquartile, on the test set, was 1.2 (0.1-6.7) for ArNet and 2.8 (0.9-11.7) for XGB for AF individuals. Generalization results on LTAF were consistent with | E AF (% ) | of 2.7 (1.1-14.7) for ArNet and 3.6 (1.0-16.7) for XGB. Conclusion: This research demonstrates the feasibility of AFB estimation from 24h beat-to-beat interval time series utilizing DRNNs. Significance: The novel data-driven approach enables robust remote diagnosis and phenotyping of AF.
No takes yet. Share an insight, caveat, or question.
Chocron et al. (2020) conducted an observational in Atrial Fibrillation (n=2,891). Deep recurrent neural network (ArNet) vs. Gradient boosting (XGB) model was evaluated on Absolute AF burden estimation error |EAF(%)|. The deep recurrent neural network ArNet estimated atrial fibrillation burden with a median absolute error of 1.2%, outperforming the gradient boosting model's error of 3.1%.