Answers are grounded in this paper and cite their sources.
Evaluates coating properties of alginate/hydroxyapatite on titanium surfaces, indicating potential for improved biomaterials.
Alginate/Hydroxyapatite (Alg/HA) composites at different ratios (Alg_pure, 5:1, 4:1, 3:1, 2:1) were deposited on titanium (Ti) surface using the dip-coating technique. The influence of composition on coating homogeneity, morphology, and physicochemical properties was systematically investigated. FITR, Raman, XRD, and SEM/EDS analyses confirmed the presence of HA phase within the polymer matrix. The Alg2:1HA coating displayed cracks in the Alg/HA interface, suggesting saturation of polymer matrix. The rheological assays displayed all suspensions exhibited non-Newtonian shear-thinning behavior. The profilometry assessments indicated that all coatings exhibited suitable micro-roughness for promoting osseointegration. SEM/FIB and optical microscopy revealed that the Alg3:1HA and Alg2:1HA coatings demonstrated good adhesion and mechanical strength when subjected to tensile stress in a three-point bending test. However, Alg3:1HA coating demonstrated a more favorable properties, with no cracks in the Alg/HA interface. Overall, these findings contribute valuable insights toward the development of bioactive, mechanically resistant coatings for orthopedic and dental applications.
No takes yet. Share an insight, caveat, or question.
Carvalho et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: