Answers are grounded in this paper and cite their sources.
Investigates structural performance of prefabricated masonry walls, suggesting efficiency benefits over traditional methods.
Off-site construction (OSC) enhances construction quality control and speed by relocating building processes to controlled environments. OSC techniques significantly improve project efficiency and consistency. This study investigates the application of OSC techniques to concrete masonry unit (CMU) construction in the form of a prefabricated modular masonry panel system for single-story, tall wall applications. Two full-scale, partially grouted, slender, unbonded posttensioned masonry walls—one constructed using a segmental prefabricated system and the other constructed monolithically— were tested to assess the structural performance of the panelized CMU system. Each wall measured 8.75 m in height, 1.19 m in width, and 0.19 m in thickness. The walls were subjected to combined eccentric axial loads and cyclic lateral out-of-plane (OOP) uniform pressure under different base conditions. Results showed that the prefabricated wall exhibited similar initial stiffness and deformation profile compared to the monolithically constructed wall under service loads. However, the monolithically constructed wall demonstrated 70% larger peak OOP resistance and 63% smaller residual deformations.
No takes yet. Share an insight, caveat, or question.
Elsayed et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: