Answers are grounded in this paper and cite their sources.
Evaluates hydrophilicity in phenolic resin coatings using various wetting agents, suggesting design guidelines for improved performance.
Phenolic resins (PRs), widely used in different technological and practical fields, tend to have a limited hydrophilic character. For coating applications where hydrophilic properties are required, wetting agents (WAs) are typically added to the PRs formulations. The hydrophilicity is in this case strongly affected by the distribution of the WAs in the coating. This distribution depends on a delicate balance between miscibility and surface segregation. Phenol-urea-formaldehyde (PUF) and phenol-formaldehyde (PF) resins-based coatings, containing various types of WAs were studied to evaluate their effect on the coating’s hydrophilicity. The most important selection criterium for effective WAs for PRs coatings was found to be the chain length of alkyl and ethylene oxide groups in the WAs. Additionally, an anionic headgroup is beneficial to achieve both sufficient miscibility with PUF during the cure process and an increase in hydrophilicity of the resulting coatings. For PF resins anionic WAs can also be used without inducing de-mixing, provided that the ethylene oxide content of the WA is sufficiently large. These insights provide a framework for the selection or design of new WAs for improved wetting performance of phenolic resin coatings.
No takes yet. Share an insight, caveat, or question.
Moone et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: