Answers are grounded in this paper and cite their sources.
Compares stimulated and unstimulated saliva collection methods for iodine assessment, suggesting stimulated saliva as more reliable.
Salivary iodide concentration (SIC) has emerged as a promising non-invasive alternative for assessing iodine status (1) . However, the influence of saliva collection method on biomarker reliability remains unclear. This study compared unstimulated and stimulated saliva collection methods and evaluated their associations with urinary iodine indices to identify the most reliable approach for iodine quantification. Twenty-nine healthy adults provided unstimulated and stimulated saliva samples two hours post-evening meal, alongside a 24-hour urine sample. The 24-h urinary iodine concentration (24 h UIC; µg/L) was measured and corrected for creatinine (24 h UI/Cr; µg/gCr). The SIC (µg/L) and protein (mg/mL) were analysed, and from these, secretion rates (µg/min; mg/min) and the protein-normalised iodide ratio (SI/P; µg/g) were calculated. Within-subject repeatability was assessed in a subgroup (n=8) across three non-consecutive days using the coefficient of variation (%CV). Unstimulated saliva showed higher median iodide (94.4 vs 59.4 µg/L; p < 0.001), protein (2.36 vs 1.90 mg/mL; p < 0.001), and SI/P (35.99 vs 29.45 µg/g; p = 0.046) concentrations than stimulated saliva, whereas flow rate was significantly higher under stimulation (1.78 vs 1.14 mL/min; p < 0.001). Despite these concentration differences, total iodide and protein secretion per minute were comparable between methods (iodide: 0.10 vs 0.10 µg/min; protein: 3.58 vs 2.94 mg/min; both p > 0.1). For unstimulated saliva, both SIC and SI/P correlated significantly with 24 h UIC (r = 0.403, p = 0.033; r = 0.429, p = 0.020, respectively) and 24 h UI/Cr (r = 0.584, p = 0.001; r = 0.592, p < 0.001).For stimulated saliva, both also correlated significantly with 24 h UI/Cr (r = 0.475, p = 0.012; r = 0.404, p = 0.041) and 24 h UIC before correction (r = 0.417, p = 0.027), but this association was no longer significant after correction (r = 0.357, p = 0.068). Across both methods, correlations with 24 h urinary iodine excretion (24 h UIE) ranged from r = 0.20 to 0.33 and were not significant, except for the salivary iodide secretion rate, which was associated significantly with 24 h UIE under stimulated conditions only (r = 0.488, p = 0.009). Across 3-days, stimulated saliva showed lower %CV than unstimulated for SIC (31.6% vs 39.0%), SI/P (34.0% vs 44.9%), and iodide secretion rate (33.1% vs 47.9%), with variability comparable to urinary biomarkers (UIC = 30.4%; UIE = 34.7%). Overall, although total iodide secretion was comparable between methods, stimulated saliva showed stronger methodological performance, supporting its use as the preferred protocol for reliable salivary iodine assessment. Both methods demonstrated moderate correlations with 24 h UIC and 24 h UI/Cr; however, for stimulated saliva, the association with 24 h UIC was significant only before protein correction. The stimulated, swab-based method yielded greater sample volume and lower intra-individual variability, and notably, the salivary iodide secretion rate under stimulated conditions was the only parameter to correlate significantly with 24 h UIE.
No takes yet. Share an insight, caveat, or question.
Alsaeedi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: