Key result
Inappropriate ICD therapy occurring during sedentary/awake conditions was associated with a increased risk of all-cause mortality compared to other conditions.
Why the study?
Inappropriate ICD therapy is common and may be associated with an increased risk of death, but risk stratification schemes for these patients are needed.
Cohort (n=417)
Yes
In patients receiving inappropriate ICD therapy, elevated BNP, nonsinus rhythm, and inappropriate therapy occurring during sedentary/awake conditions are strong predictors of mortality, enabling risk stratification via a decision tree model.
Answers are grounded in this paper and cite their sources.
Does not support practice changes in ICD recipients; leaves open whether activity context during inappropriate therapy warrants prospective validation.
Implantable cardioverter-defibrillators (ICDs) improve survival in patients who are at risk of sudden death. However, inappropriate therapy is commonly given to ICD recipients, and this situation may be associated with an increased risk of death. This study aimed to construct a risk stratification scheme by using decision tree analysis in patients who received inappropriate ICD therapy.Mortality was calculated from a retrospective data analysis of a multicenter cohort involving 417 ICD recipients. Inappropriate therapy was defined as therapy for nonventricular arrhythmias, including sinus tachycardia, supraventricular tachycardia, atrial fibrillation/flutter, oversensing, and lead failure. Inappropriate therapy included antitachycardia pacing, cardioversion, and defibrillation. The prognostic factors were identified by a Cox proportional hazards regression analysis, and we constructed a decision tree.During an average follow-up of 5.2 years, 48 patients (12%) had all-cause death. A multivariate Cox hazard model revealed that the age (hazard ratio [HR] 1.06, P < 0.001), ln B-type natriuretic peptide (BNP) (HR 1.47, P = 0.02), nonsinus rhythm at implantation (HR 2.70, P < 0.05), and inappropriate therapy occurring during sedentary/awake conditions (HR 3.51, P = 0.001) correlated with an increased risk of mortality. An inappropriate therapy due to abnormal sensing (HR 0.16, P = 0.04) decreased the risk of mortality. Furthermore, a decision tree analysis stratified the patients well by using 4 covariates: BNP, activity at the time of inappropriate therapy, mechanism of inappropriate therapy, and baseline rhythm at ICD implantation (log-rank test, P < 0.0001).We identified the predictors of mortality in inappropriate ICD therapy recipients and constructed a risk stratification scheme by using decision tree analysis.
No takes yet. Share an insight, caveat, or question.
Yamamoto et al. (2019) conducted a cohort in History of inappropriate implantable cardioverter-defibrillator (ICD) therapy (n=417). Inappropriate ICD therapy during sedentary/awake conditions vs. Inappropriate ICD therapy during other conditions was evaluated on All-cause death (HR 3.51, 95% CI 1.60-8.25, p=0.001). Inappropriate ICD therapy occurring during sedentary/awake conditions was associated with a increased risk of all-cause mortality compared to other conditions.
Synapse has enriched 10 related papers. Consider them for comparative context: