A simulation model was developed to predict ammonia emission from a scale model dairy-cow house. Themodel described the enzymatic urea degradation and volatilization of ammonia from a slatted floor after applying amixture of urine and feces or after sprinkling of urine. The parameters needed as input for the simulation model to predictthe ammonia emission for a period of 24 h were measured or taken from literature. Lack of fit occurred between the predicted and measured emission when urease-activity values from a laboratoryanalysis of a urine/feces mixture were used. A better agreement was obtained by using an urease-activity which was aboutten times higher. The need for a higher urease-activity is in accordance with the observation that due to repeated foulingof the floor the height of the emission peak measured after the application of an urine/feces mixture increased and thetime between the application of the mixture and the moment that the emission reached its peak became shorter. Thisindicated that due to repeated fouling, the amount of urease on the floor surface increased. The developed simulation model can be used as the basis for a model to predict the ammonia emission from a practicaldairy-cow house.
No takes yet. Share an insight, caveat, or question.
Elzing et al. (1997) studied this question.