Key result
Repeated severe-intensity cycling bouts unexpectedly resulted in less muscle oxygen desaturation with each subsequent effort, with mean work SmO2 increasing from 30% in bout 1 to 36% in bout 4.
Why the study?
Muscle oxygenation response to self-paced, severe-intensity cycling remains unclear.
Does self-paced severe-intensity cycling affect muscle oxygen saturation in trained cyclists?
Does self-paced severe-intensity cycling affect muscle oxygen saturation in trained cyclists?
Absolute Event Rate: 36% vs 30%
p-value: p=<0.05
Wearable NIRS sensors can reliably measure heterogeneous muscle oxygenation responses during severe intensity cycling bouts in trained cyclists.
Near-infrared spectroscopy (NIRS) quantifies muscle oxygenation (SmO 2 ) during exercise. Muscle oxygenation response to self-paced, severe-intensity cycling remains unclear. Observing SmO 2 can provide cycling professionals with the ability to assess muscular response, helping optimize decision-making. We aimed to describe the effect of self-paced severe intensity bouts on SmO 2 , measured noninvasively by a wearable NIRS sensor on the vastus lateralis (VL) muscle, and examine its reliability. We hypothesized a greater desaturation response with each bout, whereas, between trials, good reliability would be observed. Fourteen recreationally trained, and trained cyclists completed a ramp test to determine the power output (PO) at the respiratory compensation point (RCP). Athletes completed two subsequent visits of 50-minute sessions that included four severe-intensity bouts done at 5% above RCP PO. Muscle oxygenation in the VL was monitored using a wearable NIRS device. Measures included mean PO, heart-rate (HR), cadence, and SmO 2 at bout onset, during work (work SmO 2 ), and Δ SmO 2 . The bouts were compared using a one-way repeated measures ANOVA. For significant differences, a Fisher's least square difference post-hoc analysis was used. A two-way repeated measures ANOVA was used using trial and bout as main factors. Intraclass correlations (ICC) were used to quantify relative reliability for mean work, and standard error of the measurement (SEM) was used to quantify absolute agreement of mean work SmO 2 . Both PO and cadence showed no effect of bout or trial. Heart-rate at bout 2 (168 ± 8 bpm) and 4 (170 ± 7 bpm) were higher than bout 1 (160 ± 6 bpm). Onset SmO 2 (%) response significantly increased in the final two bouts of the session. Mean work SmO 2 increased across bouts, with the highest value displayed in bout 4 (36 ± 22%). Δ SmO 2 showed a smaller desaturation response during bout 4 (27 ± 10%) compared to bout 3 (31 ± 10%). Mean work SmO 2 ICC showed good reliability (ICC = 0.87), and SEM was 12% (CI 9-15%). We concluded that a non-invasive, affordable, wearable NIRS sensor demonstrated the heterogeneous muscle oxygenation response during severe intensity cycling bouts with good reliability in trained cyclists.
No takes yet. Share an insight, caveat, or question.
Yogev et al. (2023) studied Healthy trained cyclists (n=14). Severe-intensity cycling bouts vs. Bout 1 (baseline) was evaluated on Mean work muscle oxygen saturation (SmO2) (p=<0.05). Repeated severe-intensity cycling bouts unexpectedly resulted in less muscle oxygen desaturation with each subsequent effort, with mean work SmO2 increasing from 30% in bout 1 to 36% in bout 4.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: