Key result
Deep learning model for wearable ECGs achieves ~100% sensitivity for AF detection.
Why the study?
Conventional AF screening using rule-based algorithms has suboptimal accuracy and requires extensive clinician review for large ECG data volumes, while AI offers improved detection efficiency and scalability.
Does a semi-real-time ECG monitoring system integrating AI and wearable devices accurately detect atrial fibrillation in high-risk patients?
Observational (n=1,656)
No
Does a semi-real-time ECG monitoring system integrating AI and wearable devices accurately detect atrial fibrillation in high-risk patients?
An AI-integrated wearable ECG monitoring system demonstrated high sensitivity for atrial fibrillation detection and proved feasible for semi-real-time screening in high-risk populations.
Background Atrial fibrillation (AF) is a common arrhythmia associated with substantial morbidity, particularly ischemic stroke. Conventional AF screening using rule-based algorithms is limited by suboptimal accuracy and the need for extensive clinician review when processing large volumes of electrocardiogram (ECG) data. Artificial intelligence (AI) has emerged as a promising approach to improve detection efficiency and scalability. Objectives To develop and internally evaluate a deep learning model for AF screening using real-world 24-hour Holter ECG data, and to evaluate a semi–real-time monitoring workflow integrating AI and wearable ECG devices in high-risk patients. Methods This retrospective study included 1,489 Holter ECG recordings collected at Nguyen Trai Hospital. A Residual Network (ResNet) model was trained on 1,089 recordings and evaluated on an independent dataset of 400 recordings using case-level classification with patient-level data splitting. A semi–real-time screening workflow integrating AI analysis and wearable ECG devices was prospectively implemented in a high-risk cohort. Results From the training dataset, a total of 29,765 minutes of cardiologist-annotated AF episodes were identified across 82 AF-positive recordings. These episode-level annotations were subsequently mapped to fixed 60-second segments for model training using a predefined sampling strategy. On the independent evaluation dataset (n = 400; AF prevalence 6.3%), the model achieved 100.0% sensitivity, 88.0% specificity, and 35.7% positive predictive value for case-level AF detection. In the pilot cohort (n = 167), AF was detected in 24 patients (14.4%), including 20 (12.0%) identified after 24 hours of monitoring. Conclusions The proposed framework demonstrated high sensitivity for AF detection in real-world Holter ECG data. Integration with wearable devices in a semi–real-time clinician-in-the-loop workflow was feasible and may support AF screening in high-risk populations.
No takes yet. Share an insight, caveat, or question.
Nguyen et al. (2026) conducted an observational in Atrial fibrillation (n=1,656). Deep learning model (ResNet) for AF screening was evaluated on Case-level AF detection. A deep learning model for atrial fibrillation screening achieved 100.0% sensitivity, 88.0% specificity, and 35.7% positive predictive value for case-level detection on an independent dataset.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: