Key result
Combined catheter ablation and Watchman LAA occlusion achieved satisfactory LAA occlusion in 100% of patients at 12 months, with an observed stroke rate of 0.5% per year.
Why the study?
Does combined catheter ablation and Watchman LAA occlusion provide safe and effective rhythm control and stroke prevention in patients with non-valvular AF?
Observational (n=98)
No
Does combined catheter ablation and Watchman LAA occlusion provide safe and effective rhythm control and stroke prevention in patients with non-valvular AF?
Combined catheter ablation and Watchman LAA occlusion is feasible and safe, achieving excellent LAA occlusion rates and low stroke rates in patients with non-valvular AF.
Answers are grounded in this paper and cite their sources.
Should not yet change AF practice; hypothesis-generating for combined ablation-Watchman feasibility.
Background Patients with atrial fibrillation (AF) may benefit from undergoing concomitant interventions of left atrial catheter ablation and device occlusion of the left atrial appendage (LAA) as a two‐pronged strategy for rhythm control and stroke prevention. We report on the outcome of combined procedures in a single center case series over a 5‐year timeframe. Methods Ninety‐eight patients with non‐valvular AF and a mean CHA 2 DS 2 ‐VASc score 2.6±1.0 underwent either first time, or redo pulmonary vein isolation (PVI) procedures, followed by successful implant of a Watchman® device. Results All procedures were generally uncomplicated with a mean case time of 213±40 min. Complete LAA occlusion was achieved at initial implant in 92 (94%) patients. Satisfactory LAA occlusion was achieved in 100% of patients at 12 months, with a complete LAA occlusion rate of 86%. All patients discontinued oral anticoagulation. Persistent late peri‐device leaks were more frequently associated with device angulation or shoulder protrusion, and were associated with a significantly lower achieved device compression of 12±3% vs. 15±5% ( p <0.01) than complete occlusion. One ischemic stroke was recorded over a mean follow‐up time of 802±439 days. Twelve months' freedom from detectable AF was achieved in 77% of patients. Conclusions Combined procedures of catheter ablation for AF and Watchman® LAA implant appear to be feasible and safe, with excellent rates of LAA occlusion achieved and an observed stroke rate of 0.5% per year during mid‐term follow‐up. Incomplete occlusion was associated with lower achieved device compression and was more frequently associated with suboptimal device position.
No takes yet. Share an insight, caveat, or question.
Phillips et al. (2015) conducted an observational in Non-valvular atrial fibrillation (n=98). Combined catheter ablation and Watchman LAA occlusion was evaluated on Satisfactory LAA occlusion at 12 months. Combined catheter ablation and Watchman LAA occlusion achieved satisfactory LAA occlusion in 100% of patients at 12 months, with an observed stroke rate of 0.5% per year.
Synapse has enriched 10 related papers. Consider them for comparative context: