Investigates how arc current affects coating properties for roller mill roll restoration, suggesting optimal parameters.
Worn roller mill roll shafts made of Steel 45 require cost-effective surface restoration; plasma transferred arc (PTA) deposition of Ni–Cr–B–Si + WC composite coatings is a promising approach, yet the effect of arc current on coating quality remains insufficiently characterised for this substrate. Six coatings were deposited from PS-12NVK-01 powder (65 wt.% PG-10N-01 + 35 wt.% WC) at arc currents of 50–100 A on Steel 45 substrates using a ZTW3501DC PTA system; coatings were characterised by SEM, EDS mapping, XRD (HighScore Plus, PDF-2), Vickers microhardness profiling, and ball-on-flat tribological testing. EDS analysis revealed that compositional dilution increases from 18.1% at 60 A to 46.6% at 100 A; XRD identified WC + Cr3C2 + Ni3B + Ni2B + (Fe,Ni)γ at 50 A, transitioning through Cr7C3 + W2C dominance at 80 A to an Fe0.64Ni0.36 matrix at 100 A; and coating thickness peaked at 2.70 mm at 80 A. The 60 A coating yielded the highest surface hardness (887 ± 76 HV, >4× the substrate), the lowest specific wear rate (4.00 × 10−6 mm3/(N·m), ~22× lower than uncoated Steel 45), and minimum dilution (18.1%), identifying 60 A as the most favourable deposition current for the restoration of roller mill roll shafts under the process parameters employed.
No takes yet. Share an insight, caveat, or question.
Shynarbek et al. (2026) studied this question.