Answers are grounded in this paper and cite their sources.
Demonstrates effective removal of ethyl acetate and microorganisms in indoor air, suggesting a novel hybrid approach for pollution control.
This study investigates the simultaneous elimination of ethyl acetate (EA), a representative volatile organic compound (VOC), and Escherichia coli aerosols from indoor air using a continuous-flow dielectric barrier discharge (DBD) plasma reactor coupled with a photocatalytic luminous textile system (Cu/TiO2-coated fibers). The effects of applied voltage, relative humidity, and air-flow rate on pollutant removal and disinfection performance were systematically evaluated. Optimal DBD operation at 18 kV, 1 m3 h−1 airflow, and 70% relative humidity achieved single-process removal efficiencies of 77% for EA and 2 log reduction (CFU mL−1) for E. coli. When photocatalysis was coupled with DBD plasma, a significant combined effect was observed, increasing EA degradation to 87% and bacterial inactivation to 3.8 log (CFU mL−1). The coupling enhanced active-species generation, improved CO2 selectivity (up to 53%), and reduced residual ozone concentration. Humidity positively affected microbial inactivation due to °OH radical formation but slightly decreased VOC degradation by limiting ozone regeneration. Results demonstrate the efficiency and scalability of the DBD–photocatalysis hybrid system for multi-pollutant indoor air purification, offering rapid, low-temperature treatment suitable for industrial-scale applications.
No takes yet. Share an insight, caveat, or question.
Karoui et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: