Answers are grounded in this paper and cite their sources.
Thesis demonstrates improved efficiency and transient response in power converters for GPUs, suggesting effective delivery methods for data centers.
This thesis presents the design and optimization of a four-phase coupled-inductor buck converter for vertical point-of-load (POL) power delivery in state-of-the-art GPUs. A simulation workflow based on pregenerated lookup tables (LUTs) and MATLAB modeling is developed, enabling efficient evaluation of converter performance, including core and winding losses for different inductor geometries and materials. The proposed design achieves a peak efficiency of 93.8% at a current density of 1.48 A/mm², while maintaining 91.5% efficiency at a target current density of 3.2 A/mm². Furthermore, the results demonstrate that the coupled-inductor topology enables fast transient response, taking the limited area of the decoupling capacitors into account.
No takes yet. Share an insight, caveat, or question.
Tizian Falke (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: