Key result
Leadless pacemakers show comparable in-hospital death and complication rates versus transvenous pacemakers.
Why the study?
Nationwide data comparing in-hospital deaths and complications between leadless pacemakers and transvenous pacemakers in Japan remain limited.
Does leadless pacemaker implantation reduce in-hospital deaths and complications compared to conventional transvenous pacemakers in adults requiring pacing?
Cohort (n=25,198)
Yes
Does leadless pacemaker implantation reduce in-hospital deaths and complications compared to conventional transvenous pacemakers in adults requiring pacing?
Odds Ratio: 0.95 (95% CI 0.84–1.07)
Absolute Event Rate: 5.41% vs 5.59%
p-value: p=0.44
While overall in-hospital complications and mortality are similar between leadless and transvenous pacemakers, leadless pacemakers are associated with a higher risk of early mortality (within 7 days) and cardiac tamponade.
Comparable composite outcomes should not change practice; leaves open cardiac tamponade risk with leadless pacemakers.
Background: Nationwide data on in-hospital deaths and complications between leadless pacemakers (LPMs) and transvenous pacemakers (TVPMs) in Japan remain limited. Methods and Results: Using a nationwide database, we identified adults who underwent TVPM or LPM implantation between 2017 and 2023. LPM implantation increased from 0.5% to 25% (P for trend <0.001). LPMs were selected more often as patient age increased and those undergoing dialysis or with dementia and atrial fibrillation (P<0.001). After propensity score matching (12,599 per group), composite outcomes (in-hospital deaths and all complications) were comparable between the LPM and TVPM groups (5.41% vs. 5.59%, respectively; P=0.44; odds ratio [OR] 0.95; 95% confidence interval [CI] 0.84–1.07). All-cause in-hospital death did not differ between groups (LPM, 1.09%; TVPM, 1.05%; P=0.55; OR 1.07; 95% CI 0.83–1.38), whereas all-cause death within 7 days after implantation was higher in the LPM group (0.58% vs. 0.33%; P=0.003; OR 1.80; 95% CI 1.21–2.67). All complications was comparable between the LPM and TVPM groups (LPM, 4.78%; TVPM, 4.82%; P=0.59; OR 0.96; 95% CI 0.85–1.09), but cardiac tamponade was more frequent in the LPM group (0.29% vs. 0.06%; P<0.001; OR 5.42; 95% CI 2.38–12.32). Conclusions: Composite outcomes were comparable between the LPM and TVPM groups, but the rates of cardiac tamponade and all-cause death within 7 days after implantation were higher in the LPM group.
No takes yet. Share an insight, caveat, or question.
Nishimura et al. (2026) conducted a cohort in Bradyarrhythmias requiring pacemaker implantation (n=25,198). Leadless pacemaker vs. Transvenous pacemaker was evaluated on Composite of in-hospital deaths and all complications (OR 0.95, 95% CI 0.84-1.07, p=0.44). Leadless pacemakers resulted in comparable rates of the composite outcome of in-hospital death and complications compared to transvenous pacemakers (5.41% vs. 5.59%; OR 0.95).