Investigates visual field reliability and its association with Bayesian entropy in glaucoma.
PURPOSE: To investigate the association between reliability of visual field (VF) and the entropy of the Bayesian posterior distribution of the threshold. MATERIALS AND METHODS: Subjects were comprised of 122 eyes of 73 patients with primary open-angle glaucoma. The VF was measured using the newly developed variational Bayes linear regression visual field (VBLR-VF) twice within 3 months. The likelihood of this final probability distribution of the thresholds in the measured VF was calculated (Entropy index). The mean absolute error (MAE) of the total deviation (TD) values of the test-retest VFs was measured, and its relationship to fixation losses (FLs), false positives (FPs), false negatives (FNs), and the Entropy index (average of the 2 VFs) was investigated. In addition, the association between the difference in the mean deviation (MD; between 2 VFs) and the difference in the Entropy index (between 2 VFs) was investigated. CONCLUSION: The Entropy index was significantly associated with FL, FP, FN, and test-retest reproducibility. In addition, a higher Entropy index was associated with advanced VF loss, potentially indicating lower test reliability.
No takes yet. Share an insight, caveat, or question.
Asaoka et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: