Investigates flow behavior variation in tundish due to water temperature, highlighting implications for casting quality.
During continuous casting, the flow behavior of liquid steel in the tundish directly affects the temperature distribution of liquid steel, inclusion removal, and billet quality. In tundish-related research, water model experiments remain an intuitive method for investigating the flow process in the tundish. However, water model experiments are often conducted in different seasons, and variations in experimental temperature can change fluid properties such as density and viscosity, thereby affecting flow characteristics and the comparability of experimental results. In this study, a 1:3.57 transparent bare single-strand tundish model made of acrylic was used, and the differences in tracer transport processes at 7 °C and 20 °C, as well as the influence of different tracer dosages on the experimental results, were systematically investigated through flow visualization and stimulus-response experiments. The results showed that, under the 7 °C condition, the upward transport tendency of the pure ink tracer was weakened, the overall flow remained closer to the tundish bottom, the transport speed decreased, and the time required to reach the outlet was significantly prolonged. For the saturated KCl solution tracer, a lower temperature enhanced its transport along the bottom toward the outlet and suppressed its diffusion toward the liquid surface. The RTD results showed that, after the temperature was increased, the curves shifted to the left as a whole, and both the peak time and the mean residence time were shortened. The outflow percentage of tracer results showed that the difference for the 10 mL saturated KCl solution between the 7 °C and 20 °C conditions was the most significant. At 7 °C, the total outflow percentage of the 10 mL salt solution tracer at 1500 s was 76.86%, which was 22.97% lower than that at 20 °C. As the tracer dosage increased, the differences in the transport process, RTD curves, and outflow percentage curves under different temperature conditions gradually decreased, indicating that the effect of dosage on the experimental results gradually became stronger than that of temperature. These results indicate that the combined effects of experimental temperature and tracer dosage cannot be neglected in tundish water model experiments.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: