Randomized trial demonstrates anomaly detection in SMART valve systems, indicating robust diagnostics for safety-critical applications.
Reliable anomaly detection and diagnosis are critical for the safe operation of complex engineered systems. This study presents a unified framework that integrates statistical, model-based, and data-driven techniques for anomaly detection and investigation, demonstrated on SMART valve systems in hybrid energy applications. Four detection methods—mean deviation, seasonal extreme studentized deviate, ARIMA forecasting, and matrix profiling—were implemented and compared. Matrix profiling was particularly effective in revealing subtle deviations and hidden relationships among variables. Anomaly investigation was performed by analyzing variable-level and grouped signal profiles, with system topology incorporated to distinguish primary faults from propagated effects. Grouping signals by type enhanced interpretability, enabling accurate localization of anomalies across multi-dimensional datasets. Experimental results confirmed the framework’s capability to consistently detect and isolate anomalies while providing actionable insights into system interdependencies. The proposed methodology offers a robust, interpretable, and scalable solution for condition monitoring, with potential applications in safety-critical domains such as nuclear energy, aerospace, and process industries.
No takes yet. Share an insight, caveat, or question.
Ifeanyi et al. (2026) studied this question.