Key result
Mechanical circulatory support with an Impella CP device successfully bridged a patient with thyrotoxicosis-induced cardiogenic shock to full clinical recovery.
Why the study?
Does mechanical circulatory support serve as an effective bridge to recovery in a patient with thyrotoxicosis-induced cardiogenic shock?
Case Report (n=1)
No
Does mechanical circulatory support serve as an effective bridge to recovery in a patient with thyrotoxicosis-induced cardiogenic shock?
Mechanical circulatory support devices such as Impella can be a useful bridging tool in reversible causes of cardiogenic shock, including thyroid storm.
Answers are grounded in this paper and cite their sources.
May support Impella as bridge in thyrotoxicosis cardiomyopathy; leaves open need for randomized confirmation before practice change.
Thyroid storm is a life-threatening condition which, in rare cases, may lead to cardiogenic shock and dysrhythmias. Mechanical circulatory support with an Impella device or extracorporeal membrane oxygenation may be used as a bridge to recovery in these cases. This case involves a patient with thyrotoxicosis and reduced ejection fraction and hemodynamic instability requiring Impella device placement. After treatment with methimazole, Lugol's iodine, and hydrocortisone, he was weaned off mechanical circulatory support and made a full recovery. Mechanical circulatory support devices can be a useful bridging tool in reversible causes of cardiogenic shock, such as thyroid storm.
No takes yet. Share an insight, caveat, or question.
Dhir et al. (2022) conducted a case report in Thyrotoxicosis-induced cardiomyopathy (n=1). Impella CP (Mechanical circulatory support) was evaluated on Hemodynamic improvement and clinical recovery. Mechanical circulatory support with an Impella CP device successfully bridged a patient with thyrotoxicosis-induced cardiogenic shock to full clinical recovery.