Despite efforts to reduce radiation exposure, concerns remain regarding the safety and added procedure time of fluoroless left-sided catheter ablations.
Does a radiofrequency transseptal wire allow for safe and effective completely fluoroless transseptal puncture and ablation in patients with left-sided cardiac arrhythmias?
Does a radiofrequency transseptal wire allow for safe and effective completely fluoroless transseptal puncture and ablation in patients with left-sided cardiac arrhythmias?
The use of a radiofrequency transseptal wire enables safe, efficient, and completely fluoroless transseptal puncture for left-sided catheter ablations, eliminating radiation exposure for patients and staff.
Supports feasibility of fluoroless transseptal access; hypothesis-generating and should not yet change practice.
PURPOSE: Conventional catheter ablation for atrial fibrillation requires fluoroscopy, which has inherent risks of radiation exposure to patients and medical staff. Optimization of fluoroscopy parameters and use of three-dimensional electroanatomic mapping (EAM) and intracardiac echocardiography (ICE) have helped to reduce radiation exposure; however, despite growing evidence, there are still concerns about safety and added procedure time associated with fluoroless procedures, particularly in left-sided ablations, due to the potential risk of complications. Herein, we report our initial experience using a radiofrequency (RF) wire for completely fluoroless radiofrequency ablation (RFA) and cryoballoon ablation (CBA). METHODS: A retrospective analysis was conducted on ablation procedures for various cardiac arrhythmias performed non-fluoroscopically at two centers using the VersaCross RF wire transseptal system under EAM and ICE guidance. RESULTS: A total of 72 and 54 patients underwent RFA and CBA, respectively, successfully without any procedural complications. Transseptal access time for RFA was 14.5 ± 6.6 min from procedure start (including sheath and catheter placements ± right-sided ablation) or 2.8 ± 1.0 min from RF wire insertion into the femoral introducer. Transseptal access time for CBA was 19.2 ± 11.7 min from procedure start (including sheath and catheter placements ± right-sided ablation) or 3.5 ± 1.6 min from RF wire insertion into the femoral introducer. Average procedure time was 104.4 ± 38.0 min for RFA and 91.1 ± 22.1 min for CBA. CONCLUSIONS: A RF wire can be used to achieve completely fluoroless transseptal puncture safely and effectively while improving procedural efficiency in both RFA and CBA.
No takes yet. Share an insight, caveat, or question.
Demo et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: