Develops a dual-metric framework for assessing long-term indoor air quality in academic buildings, indicating a need for improved ventilation management.
Indoor air quality (IAQ) assessment and control in academic buildings is an engineering challenge due to high occupant density, fixed class schedules, and prolonged daily use, which together create sustained exposure conditions not captured by short-term measurements. Most existing IAQ studies in educational environments rely on short-term monitoring and concentration-based compliance metrics, limiting their ability to quantify cumulative exposure and long-term ventilation performance. This study develops and applies a long-term, occupancy-aware exposure assessment framework for indoor carbon dioxide (CO2) based on continuous sensor data. An exceedance-based Health Exposure Index (HEI) and a Cumulative Exposure Index (CEI) are formulated using time-resolved CO2 measurements and schedule-based student occupancy weighting. HEI quantifies the intensity and duration of concentration exceedance above engineering thresholds (800, 1000, and 1600 ppm), while CEI captures cumulative exposure above background concentration. The framework is demonstrated using 5-minute resolution data collected from January 2025 to March 2025 in a historic academic building at Schreiner University (ASHRAE Climate Zone 2B). Results show clear distinctions between non-instructional and instructional operations. During winter break, indoor CO2 remains near the outdoor background (420 ppm), whereas during academic periods, concentrations increase sharply, reaching peak values of approximately 1211 ppm (63.9% increase). Daily analysis indicates that HEI can remain zero on instructional days when thresholds are not exceeded, while CEI remains positive, revealing persistent exposure not captured by exceedance metrics alone. Monthly results show HEI increasing from 159.1 in January to 427.8 in February and 1221.7 in March, indicating progressively more frequent and severe ventilation stress, while CEI increases more gradually from 162.4 ppm to 485.5 ppm. Seasonal aggregation (January-March) yields a HEI of 589.7 and a CEI of 344.4 ppm. The results demonstrate that threshold-based compliance metrics alone are insufficient for evaluating long-term IAQ performance in academic buildings. The proposed dual-metric framework provides an engineering-relevant, scalable approach for quantifying both exceedance severity and cumulative exposure, supporting improved ventilation evaluation and long-term IAQ management in educational facilities.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: