Key result
Coronary artery distensibility measured by 64-slice CTA was significantly lower in patients with CAD compared to healthy subjects (P < 0.05) and correlated with the extent of disease.
Why the study?
Can 64-slice computed tomographic angiography (CTA) noninvasively measure coronary artery distensibility, and does it correlate with the extent of coronary artery disease in adults under 55?
Cross-Sectional (n=60)
Can 64-slice computed tomographic angiography (CTA) noninvasively measure coronary artery distensibility, and does it correlate with the extent of coronary artery disease in adults under 55?
p-value: p=<0.05
64-slice CTA can noninvasively measure coronary artery distensibility, which is significantly decreased in patients with coronary artery disease and correlates with disease extent.
May support CTA assessment of coronary distensibility; leaves open its added value for CAD detection or risk stratification.
OBJECTIVE: To test 2 hypotheses: first, that coronary distensibility can be measured noninvasively using 64-slice computed tomographic angiography (CTA); and second, that the extent of coronary artery disease (CAD) in any individual patient is related to the degree of distensibility detected by CTA. MATERIALS AND METHODS: Computed tomographic angiography was performed in 30 healthy adults and in 30 patients. All subjects were younger than 55 years. The main lesion located in the left anterior descending branch in patients with CAD. The cross-sectional coronary area of the left main and the left anterior descending arteries were measured in each phase (5%-95%, 10% each), and any change in the ratio was quantified. A distensibility value (D value) was determined for each artery. RESULTS: Compared with healthy subjects, the coronary area of the patients with CAD was significantly decreased in 65% to 85% (P < 0.05). There was a significant difference in the D value between healthy subjects and patients with both single-vessel and 2-vessel disease (P < 0.05). CONCLUSIONS: Coronary artery distensibility can be measured noninvasively using data obtained from CTA. The distensibility of the coronary artery decreased with the increasing number of involved pathological coronary vessels. The distensibility of the coronary artery correlated with the extent of CAD.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2014) conducted a cross-sectional in Coronary artery disease (n=60). Coronary artery disease vs. Healthy subjects was evaluated on Coronary artery distensibility (D value) and cross-sectional coronary area (p=<0.05). Coronary artery distensibility measured by 64-slice CTA was significantly lower in patients with CAD compared to healthy subjects (P < 0.05) and correlated with the extent of disease.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: