Key result
CT-derived extracellular volume fraction was lower in patients with dual AS-ATTR pathology compared to lone ATTR.
Why the study?
Does CT-derived extracellular volume fraction accurately differentiate between lone aortic stenosis, dual AS-ATTR pathology, and lone ATTR?
Observational (n=138)
Does CT-derived extracellular volume fraction accurately differentiate between lone aortic stenosis, dual AS-ATTR pathology, and lone ATTR?
Answers are grounded in this paper and cite their sources.
CT-ECV is lower in patients with dual AS-ATTR pathology compared to lone ATTR, resulting in a lower optimal cut-off value for differentiating AS-ATTR from lone AS compared to differentiating lone ATTR from lone AS.
AIMS: To investigate CT-derived extracellular volume fraction (CT-ECV) in patients with lone aortic stenosis (AS), dual pathology of AS and transthyretin cardiac amyloidosis (AS-ATTR), and lone ATTR, and to examine the diagnostic performance and optimal cut-off values of CT-ECV for differentiating between patients with lone AS and AS-ATTR and between patients with lone AS and lone ATTR. METHODS AND RESULTS: This retrospective study included consecutive patients with severe AS (including lone AS and AS-ATTR) and lone ATTR who underwent CT-ECV analysis and technetium 99 m pyrophosphate (99mTc-PYP) scintigraphy. The diagnostic performance of CT-ECV for detecting cardiac amyloidosis was evaluated using the area under the receiver operating characteristic curve (AUC). Of 138 patients (mean age, 80 ± 8; 96 men), 55 had lone AS, 19 had AS-ATTR, and 64 had lone ATTR. CT-derived extracellular volume fraction of patients with lone AS was 31 ± 5%. CT-derived extracellular volume fraction was significantly lower in patients with AS-ATTR than lone ATTR (45 ± 12% vs. 53 ± 13%, P = 0.04). The AUC for differentiating patients with AS-ATTR from lone AS was lower than for lone ATTR from lone AS [0.90 (95% CI: 0.81, 0.96) vs. 0.95 (95% CI: 0.90, 0.98)]. The cut-off values of CT-ECV for differentiation between patients with lone AS and AS-ATTR were lower than those between patients with lone AS and lone ATTR [36.6% vs. 38.5% (Youden index)]. There was no significant difference in the proportion of 99mTc-PYP scintigraphy grade between patients with AS-ATTR and lone ATTR (P = 0.20). CONCLUSION: Despite no significant difference in degree of ATTR between patients with AS-ATTR and lone ATTR, CT-ECV of patients with dual AS-ATTR pathology was significantly lower than that of patients with lone ATTR. The diagnostic performance and optimal cut-off values of CT-ECV for differentiating between patients with lone AS and AS-ATTR were lower than those between patients with lone AS and lone ATTR.
No takes yet. Share an insight, caveat, or question.
Kidoh et al. (2024) conducted an observational in Severe aortic stenosis and/or transthyretin cardiac amyloidosis (n=138). Dual pathology of AS and ATTR (AS-ATTR) vs. Lone ATTR was evaluated on CT-derived extracellular volume fraction (CT-ECV) (p=0.04). CT-derived extracellular volume fraction was lower in patients with dual AS-ATTR pathology compared to lone ATTR.