Study employs an optimal control strategy for energy storage in microgrids, indicating enhanced efficiency and cost reduction.
Microgrid energy storage systems necessitate coordinated control with distributed power sources to achieve optimal power distribution. Conventional strategies, including model predictive control (MPC) and approximate dynamic programming (ADP), are often hindered by high computational complexity or limited adaptability in dynamic environments. To address these limitations, this paper proposes a novel optimal control method that integrates fast dynamic programming with a gradient-based aging cost adjustment strategy. Unlike conventional ADP methods that rely on neural networks for function approximation, the proposed approach employs an extreme learning machine (ELM) to enhance both approximation accuracy and computational efficiency. A sub-gradient calculation method is further developed to dynamically balance the aging cost among storage units. The proposed method optimizes charge/discharge cycles and minimizes operational costs while adhering to constraints related to power output, state of charge (SoC), and line losses. Experimental results demonstrate that the method achieves stable power output, reduces operational cost (0.0225 yuan/kWh), and extends the battery energy storage system (BESS) lifespan through balanced usage across units.