Key result
Wearable SeismoWatch tracks 24-hour diastolic blood pressure within ~3 mmHg of standard home cuffs.
Why the study?
The authors sought to develop and evaluate a wearable watch-based device to provide noninvasive, cuff-less blood pressure estimation in an at-home setting.
Does a wearable watch-based device estimating blood pressure via pulse transit time accurately correlate with standard oscillometric cuff measurements in an at-home setting?
Observational (n=21)
No
Does a wearable watch-based device estimating blood pressure via pulse transit time accurately correlate with standard oscillometric cuff measurements in an at-home setting?
This study demonstrates the feasibility of using a noninvasive, multi-sensor wearable watch to continuously estimate blood pressure at home via pulse transit time.
Answers are grounded in this paper and cite their sources.
Supports wearable BP estimation feasibility at home; leaves open prospective validation in larger hypertensive cohorts.
OBJECTIVE: We developed a wearable watch-based device to provide noninvasive, cuff-less blood pressure (BP) estimation in an at-home setting. METHODS: The watch measures single-lead electrocardiogram (ECG), tri-axial seismocardiogram (SCG), and multi-wavelength photoplethysmogram (PPG) signals to compute the pulse transit time (PTT), allowing for BP estimation. We sent our custom watch device and an oscillometric BP cuff home with 21 healthy subjects, and captured the natural variability in BP over the course of a 24-hour period. RESULTS: After calibration, our Pearson correlation coefficient (PCC) of 0.69 and root-mean-square-error (RMSE) of 2.72 mmHg suggest that noninvasive PTT measurements correlate with around-the-clock BP. Using a novel two-point calibration method, we achieved a RMSE of 3.86 mmHg. We further demonstrated the potential of a semi-globalized adaptive model to reduce calibration requirements. CONCLUSION: This is, to the best of our knowledge, the first time that BP has been comprehensively estimated noninvasively using PTT in an at-home setting. We showed a more convenient method for obtaining ambulatory BP than through the use of the standard oscillometric cuff. We presented new calibration methods for BP estimation using fewer calibration points that are more practical for a real-world scenario. SIGNIFICANCE: A custom watch (SeismoWatch) capable of taking multiple BP measurements enables reliable remote monitoring of daily BP and paves the way towards convenient hypertension screening and management, which can potentially reduce hospitalizations and improve quality of life.
No takes yet. Share an insight, caveat, or question.
Ganti et al. (2020) conducted an observational in Healthy volunteers (n=21). SeismoWatch (wearable cuff-less blood pressure estimation via pulse transit time) vs. Oscillometric BP cuff (Omron BP785N) was evaluated on Accuracy of noninvasive blood pressure estimation (correlation and error vs. standard cuff) (Pearson correlation coefficient (PCC) of 0.69 and root-mean-square-error (RMSE) of 2.72 mmHg). The wearable SeismoWatch device accurately estimated around-the-clock diastolic blood pressure with a Pearson correlation coefficient of 0.69 and a root-mean-square-error of 2.72 mmHg compared to a standard oscillometric cuff at home.