Key result
The proposed adaptive filtering method effectively cancelled ECG artifacts in both swallow-induced and inspiration-related EMG signals, outperforming the conventional least mean square algorithm.
A novel adaptive filtering algorithm effectively removes ECG artifacts from intraoesophageal EMG signals without distorting the underlying muscle activity.
Answers are grounded in this paper and cite their sources.
May improve esophageal EMG signal fidelity in research; leaves open prospective clinical validation.
This paper presents a new and effective adaptive filtering method for the cancellation of electrocardiogram (ECG) artifacts in the electromyographic (EMG) signals obtained through intraoesophageal electrodes. This technique requires adjustable filter weights and two input signals. The primary input signal was the EMG signal containing the ECG artifact and the reference or the second input was the ECG signal measured simultaneously by two chest electrodes. The adaptive filter weights were initially set at zero and iteratively adjusted according to a least mean square algorithm proposed in this paper. The filter weights were adjusted in such a way that the output of the adaptive filter was a replica of the contaminating ECG signal, which was then subtracted from the EMG signal, yielding an ECG‐free EMG signal. The performance of the proposed method was investigated using computer simulations. It was found that ECG artifacts could be effectively cancelled while the EMG signal was not affected by adaptive filtering. Its applications showed that the proposed new algorithm had better performance than the conventional least mean square algorithm. The EMG signals were obtained in six healthy subjects, during swallows (oesophageal muscle EMG) and deep inspiration (crural diaphragm EMG). Our results demonstrated the effective cancellation of the ECG artifact in both swallow‐induced and inspiration‐related EMG signals. Spectral analysis of the EMG was performed on the ECG‐free EMG signal. The inspiration‐related EMG signal was found to have higher frequency components than the swallow‐related EMG.
No takes yet. Share an insight, caveat, or question.
CHEN et al. (1994) studied Healthy subjects (n=6). Adaptive filtering method (least mean square algorithm) for ECG artifact cancellation vs. Conventional least mean square algorithm was evaluated on Cancellation of ECG artifacts in EMG signals. The proposed adaptive filtering method effectively cancelled ECG artifacts in both swallow-induced and inspiration-related EMG signals, outperforming the conventional least mean square algorithm.
Synapse has enriched 10 related papers. Consider them for comparative context: