Key result
Acute preload reduction from hemodialysis decreased 3-dimensional principal strain from -38.10% to -35.33%, demonstrating that 3D strain parameters are volume-dependent.
Why the study?
Does acute preload reduction via hemodialysis affect 3-dimensional echocardiographic deformation parameters in patients with end-stage renal disease?
Observational (n=58)
Single-blind
No
Does acute preload reduction via hemodialysis affect 3-dimensional echocardiographic deformation parameters in patients with end-stage renal disease?
Three-dimensional echocardiographic strain parameters, including principal strain, twist, and torsion, are significantly affected by acute preload reduction and should be interpreted with caution regarding patient volume status.
Answers are grounded in this paper and cite their sources.
3D strain parameters warrant caution in volume-altered patients; leaves open their incremental value beyond 2D measures in ESRD.
BACKGROUND: Strain analysis is feasible using three-dimensional (3D) echocardiography. This approach provides various parameters based on speckle tracking analysis from one full-volume image of the left ventricle; however, evidence for its volume independence is still lacking. METHODS: Fifty-eight subjects who were examined by transthoracic echocardiography immediately before and after hemodialysis (HD) were enrolled. Real-time full-volume 3D echocardiographic images were acquired and analyzed using dedicated software. Two-dimensional (2D) longitudinal strain (LS) was also measured for comparison with 3D strain values. RESULTS: Longitudinal (pre-HD: -24.57 ± 2.51, post-HD: -21.42 ± 2.15, P < 0.001); circumferential (pre-HD: -33.35 ± 3.50, post-HD: -30.90 ± 3.22, P < 0.001); and radial strain (pre-HD: 46.47 ± 4.27, post-HD: 42.90 ± 3.61, P < 0.001) values were significantly decreased after HD. The values of 3D principal strain (PS), a unique parameter of 3D images, were affected by acute preload changes (pre-HD: -38.10 ± 3.71, post-HD: -35.33 ± 3.22, P < 0.001). Twist and torsion values were decreased after HD (pre-HD: 17.69 ± 7.80, post-HD: 13.34 ± 6.92, P < 0.001; and pre-HD: 2.04 ± 0.86, post-HD:1.59 ± 0.80, respectively, P < 0.001). The 2D LS values correlated with the 3D LS and PS values. CONCLUSION: Various parameters representing left ventricular mechanics were easily acquired from 3D echocardiographic images; however, like conventional parameters, they were affected by acute preload changes. Therefore, strain values from 3D echocardiography should be interpreted with caution while considering the preload conditions of the patients.
No takes yet. Share an insight, caveat, or question.
Ahn et al. (2017) conducted an observational in End-stage renal disease (ESRD) (n=58). Hemodialysis (acute preload reduction) vs. Pre-hemodialysis state was evaluated on 3-dimensional principal strain (PS) (p=<0.001). Acute preload reduction from hemodialysis decreased 3-dimensional principal strain from -38.10% to -35.33%, demonstrating that 3D strain parameters are volume-dependent.
Synapse has enriched 10 related papers. Consider them for comparative context: