Key result
Novel CUBIC-SWITCH imaging enables high-resolution 3D reconstructions in ~80% of calcified aortic valves.
Why the study?
Calcific aortic valve stenosis causes structural alterations in the aortic valve, but its neuroanatomical landscape remains poorly understood because standard tissue clearing protocols have limited efficacy in mineralized tissues.
Cross-Sectional (n=53)
No
An optimized CUBIC and SWITCH tissue clearing method enables high-resolution 3D mapping of the previously obscured neural architecture in densely calcified human aortic valves.
Answers are grounded in this paper and cite their sources.
May advance 3D mapping of valve innervation; hypothesis-generating for neural roles in aortic stenosis pathogenesis.
Calcific aortic valve stenosis (CAVS) is characterized by significant structural alterations in the aortic valve. However, its neuroanatomical landscape remains poorly understood. In this study, we developed an optimized three-dimensional (3D) imaging approach that combined enhanced Clear, Unobstructed Brain Imaging Cocktails and Computational (CUBIC) tissue clearing and SWITCH-Off/On to visualize the neuronal architecture within calcified human aortic valves derived from patients undergoing aortic valve replacement surgery. Standard CUBIC analysis protocols have shown limited efficacy owing to poor clearing and antibody penetration in mineralized tissues. By integrating SWITCH chemistry before decalcification and refractive index matching, we achieved uniform delipidation, fluorescence preservation, and deep tissue labelling. Light-sheet fluorescence microscopy enabled high-resolution 3D reconstructions with an 80% success rate, revealing heterogeneous and spatially organized neuronal distributions across the aortic valve. This method offers a robust platform for studying valve innervation and its potential role in mechanosensing and disease progression, opening perspectives for neuro-targeted interventions in valvular heart disease.
No takes yet. Share an insight, caveat, or question.
Bergeon et al. (2025) conducted a cross-sectional in Calcific aortic valve stenosis (CAVS) (n=53). Optimized CUBIC tissue clearing combined with SWITCH chemistry vs. Standard CUBIC tissue clearing protocol was evaluated on Successful staining and 3D imaging (distinct staining without background, adequate signal intensity, and specificity of labelling). An optimized 3D imaging approach combining CUBIC tissue clearing and SWITCH chemistry achieved an 80% success rate in high-resolution 3D reconstructions of calcified human aortic valves.
Synapse has enriched 10 related papers. Consider them for comparative context: