Randomized trial demonstrates enhanced sensitivity in quantifying ametryn in zebrafish tissues, suggesting a reliable method for toxicology research.
Rationale Ametryn poses significant risks to aquatic ecosystems, but conventional MRM methods suffer from matrix interference and limited sensitivity. To overcome these limitations, we established a more selective and sensitive UHPLC‐MS 3 approach that effectively suppresses background noise and enhances signal‐to‐noise ratio, enabling reliable quantification of ametryn in zebrafish tissues. Methods A novel UHPLC‐MS 3 method with electrospray ionization was developed. Quantification employed the MS 3 transition m/z 228.0 → 186.1 → 158.0. Five zebrafish tissues (liver, muscle, brain, intestine, gill) were analyzed following sample preparation. Fast chromatographic separation was achieved in 2.8 min. Results Compared with MRM, the MS 3 method substantially reduced matrix interference, enhanced signal intensity from 6.4 × 10 4 to 1.6 × 10 7 cps, and increased the signal‐to‐noise ratio from 6.3 to 45. The assay exhibited excellent linearity (10–1000 pg/mL), and validation results for accuracy, precision, recovery, matrix effects, and stability all met FDA bioanalytical requirements. Conclusions This study presents the first application of UHPLC‐MS 3 for quantitative analysis of ametryn in multiple zebrafish tissues, providing a reliable high‐throughput platform for residue monitoring and mechanistic toxicology research.
No takes yet. Share an insight, caveat, or question.
Yue et al. (2026) studied this question.