Answers are grounded in this paper and cite their sources.
Demonstrates real-time monitoring of cysteine-based ADCs, indicating improved process efficiency.
The manufacturing of cysteine-based antibody-drug conjugates (ADCs) requires precise control of the drug-to-antibody ratio (DAR), a critical quality attribute influencing product safety and efficacy. Conventional analytical techniques used for DAR determination, such as hydrophobic interaction chromatography (HIC) and reversed-phase high-performance liquid chromatography (RP-HPLC), are low-throughput and unsuitable for real-time process monitoring, limiting process development efficiency. To address this challenge, we developed a high-throughput size-exclusion chromatography-mass spectrometry (SEC-MS) workflow with and without postcolumn denaturation (PCD) functionality, enabling real-time monitoring of both reduction and conjugation kinetics during cysteine-based ADC manufacturing. Using a short SEC column coupled to a mass spectrometer, analysis time can be performed under 2 min per sample. This workflow was applied to rapidly optimize critical process parameters, including reductant concentration and pH during reduction, and drug-linker ratio during conjugation. The approach provided deeper mechanistic insights into reaction kinetics and supports process analytical technology (PAT)-enabled strategies for advanced process control. Overall, this high-throughput SEC-MS workflow accelerates ADC development while improving manufacturing robustness.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: