Prospective before-after study shows improved hand hygiene quality in healthcare workers using real-time feedback.
Background: Healthcare-associated infections (HAIs) remain a critical patient safety challenge. Hand hygiene is considered the most effective preventive measure, yet traditional monitoring captures only compliance, not technique quality. This prospective before–after study evaluated whether real-time visual feedback via the Semmelweis UV-fluorescence system is associated with improved hand hygiene quality, measured by ATP bioluminescence and microbiological culture. Methods: Three clinical departments (the Intensive Care Unit, Hematology, and Gynecology) at a Romanian tertiary hospital were purposively selected. Seventy-one healthcare workers (HCWs) were enrolled. The 12-week study comprised Phase 1 (baseline, weeks 1–4), Phase 2 (active intervention with Semmelweis feedback, weeks 5–8), a one-week washout (week 9), and Phase 3 (sustainability assessment, weeks 10–12). Paired ATP-CFU samples were collected weekly. Within-group comparisons used Kruskal–Wallis H tests with post hoc Dunn’s tests and Bonferroni correction. Secondary outcomes included Semmelweis global and zone-specific coverage and the correlation between subject-level Semmelweis coverage and ATP bioluminescence (Spearman’s rho). Results: A total of 781 paired ATP-CFU samples and 497 Semmelweis evaluations were analyzed. Mean ATP declined from 195.9 RLU at baseline to 148.2 RLU in Phase 2 (−24.4%) and 154.8 RLU in Phase 3 (−21.0%; Kruskal–Wallis H = 102.73, p < 0.001). CFU/mL declined from 84.8 to 66.2 (−21.9%) and 70.7 (−16.6%; H = 22.48, p < 0.001). Post hoc comparisons confirmed significant Phase 1 versus Phase 2 and Phase 1 versus Phase 3 differences for both markers (all p < 0.01), while Phase 2 versus Phase 3 was non-significant, indicating stabilization at an improved level. Subject-level Semmelweis coverage correlated negatively with ATP (rho = −0.665, 95% CI −0.778 to −0.510, p < 0.001), supporting construct validity at the operator level. Semmelweis global coverage was 93.1% (Phase 2) and 90.6% (Phase 3); interdigital spaces showed the highest inadequacy rate (73.9% protocol-based, 92.5% targeted). Conclusions: Real-time visual feedback via UV-fluorescence imaging was associated with significant and sustained improvements in hand hygiene quality beyond baseline. ATP, CFU, and Semmelweis assessments captured complementary, non-redundant dimensions, supporting multimodal evaluation. Interdigital spaces and fingertips remained persistent failure points requiring targeted educational reinforcement.
No takes yet. Share an insight, caveat, or question.
Radu et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: