Key result
High-density 8-spline mapping is linked to ~47% greater first-pass accessory pathway elimination vs conventional catheters.
Why the study?
The impact of catheter design on mapping performance and procedural outcomes during open-window mapping for accessory pathway localization remains unclear.
Does an 8-spline high-density catheter improve mapping efficiency and first-pass ablation success compared to a conventional 5-spline catheter in patients undergoing OWM-guided accessory pathway ablation?
Cohort (n=43)
Does an 8-spline high-density catheter improve mapping efficiency and first-pass ablation success compared to a conventional 5-spline catheter in patients undergoing OWM-guided accessory pathway ablation?
The use of an 8-spline high-density catheter for accessory pathway mapping significantly improves mapping efficiency and first-pass ablation success compared to a conventional 5-spline catheter.
May improve first-pass success and mapping efficiency in accessory pathway ablation; leaves open randomized confirmation.
Background Open‐window mapping (OWM) using the extended early‐meets‐late (EEML) algorithm is widely used for accessory pathway (AP) localization. However, the impact of catheter design on mapping performance and procedural outcomes remains unclear. Methods We retrospectively analyzed 43 consecutive patients undergoing OWM‐guided AP ablation. Twenty‐four patients were mapped using an 8‐spline high‐density catheter and 19 using a conventional 5‐spline catheter. Mapping characteristics and ablation outcomes were compared. Results The 8‐spline catheter was associated with higher mapping density (7974 [5618–11 017] vs. 2485 [734–12 577] points; p < 0.001) and shorter mapping time (11.0 [8.5–14.8] vs. 28.0 [15.0–40.0] minutes; p < 0.001). The EEML‐derived AP gap width was narrower in the 8‐spline group (6.1 [5.3–7.5] vs. 8.3 [2.9–15.6] mm; p = 0.023), with lower EEML thresholds required for visualization ( p = 0.003). First‐pass AP elimination was achieved in all patients in the 8‐spline group (100%) compared with 68% in the 5‐spline group ( p = 0.004), with fewer radiofrequency applications required ( p = 0.048). Fluoroscopy time and complication rates were similar between groups. Conclusion Compared with a conventional 5‐spline catheter, an 8‐spline high‐density catheter was associated with improved mapping efficiency and a higher rate of first‐pass ablation success. These findings suggest that catheter design may influence procedural performance in OWM‐guided AP ablation.
No takes yet. Share an insight, caveat, or question.
Iimura et al. (2026) conducted a cohort in Accessory pathway (n=43). 8-spline high-density catheter vs. Conventional 5-spline catheter was evaluated on First-pass accessory pathway elimination (p=0.004). Mapping with an 8-spline high-density catheter achieved a 100% first-pass accessory pathway elimination rate compared to 68% with a conventional 5-spline catheter (p=0.004).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: