Key result
Three computational methodologies for predicting cFFR yielded a similar accuracy of 6.5% to 10.5% mean absolute difference between computed and measured FFR.
Why the study?
It was unclear whether reported differences in cFFR sensitivity and specificity across studies stem from study design, patient population, or computational methodology.
How do different computational methodologies compare in their diagnostic performance for predicting coronary CT angiography-derived fractional flow reserve?
How do different computational methodologies compare in their diagnostic performance for predicting coronary CT angiography-derived fractional flow reserve?
Answers are grounded in this paper and cite their sources.
Reduced-order computational models can achieve similar accuracy to 3D models for estimating CT-derived FFR, potentially simplifying the workflow by omitting lumped pressure-drop models for stenoses.
Non-invasive coronary computed tomography (CT) angiography-derived fractional flow reserve (cFFR) is an emergent approach to determine the functional relevance of obstructive coronary lesions. Its feasibility and diagnostic performance has been reported in several studies. It is unclear if differences in sensitivity and specificity between these studies are due to study design, population, or "computational methodology." We evaluate the diagnostic performance of four different computational workflows for the prediction of cFFR using a limited data set of 10 patients, three based on reduced-order modelling and one based on a 3D rigid-wall model. The results for three of these methodologies yield similar accuracy of 6.5% to 10.5% mean absolute difference between computed and measured FFR. The main aspects of modelling which affected cFFR estimation were choice of inlet and outlet boundary conditions and estimation of flow distribution in the coronary network. One of the reduced-order models showed the lowest overall deviation from the clinical FFR measurements, indicating that reduced-order models are capable of a similar level of accuracy to a 3D model. In addition, this reduced-order model did not include a lumped pressure-drop model for a stenosis, which implies that the additional effort of isolating a stenosis and inserting a pressure-drop element in the spatial mesh may not be required for FFR estimation. The present benchmark study is the first of this kind, in which we attempt to homogenize the data required to compute FFR using mathematical models. The clinical data utilised in the cFFR workflows are made publicly available online.
No takes yet. Share an insight, caveat, or question.
Carson et al. (2019) studied Obstructive coronary lesions (n=10). Computational methodologies for predicting cFFR vs. Clinical FFR measurements was evaluated on Mean absolute difference between computed and measured FFR. Three computational methodologies for predicting cFFR yielded a similar accuracy of 6.5% to 10.5% mean absolute difference between computed and measured FFR.
Synapse has enriched 10 related papers. Consider them for comparative context: