PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 21, 2026Journal of Synchrotron Radiation0 citationsOpen Access

SiC resistive X-ray beam monitor for intensity and position control of synchrotron light

View Full Paper
GTG. TrovatoNRNiccolò La RosaFVFrancesco La Via

Key Points

  • The aim is to present a silicon carbide X-ray beam position monitor that offers enhanced performance for synchrotron light applications.
  • Developed a resistive X-ray beam position monitor utilizing a SiC membrane.
  • Characterized the device at the BESSY II synchrotron facility using 5.4 keV X-rays.
  • Used COMSOL simulations to model charge transport and validate experimental results.
  • Achieved an average transmission of approximately 61% with good spatial uniformity.
  • Demonstrated linear position response over ±500 µm and ±1 mm ranges with position sensitivities exceeding 0.157 mm −1.
  • Confirmed independence of position sensitivity from beam spot size under varying operating conditions.

Abstract

A silicon carbide (SiC) X-ray beam position monitor is presented, based on a resistive charge-division principle derived from lateral-effect photodiodes and specifically adapted for synchrotron radiation applications. This device, referred to as a resistive X-ray beam position monitor (rXBPM), exploits a free-standing SiC membrane combined with a resistive p + -doped layer, enabling transmission-mode operation while preserving high radiation hardness and mechanical robustness. In contrast to conventional segmented X-ray beam position monitors, whose response depends strongly on the beam spot size and is typically limited to narrow linear regions, the resistive architecture of the rXBPM provides an intrinsically beam-footprint-independent position signal with an extended linear response region. The detector was fabricated using selective electrochemical etching to realize a thin membrane structure and was experimentally characterized at the microfocus beamline (MiFo) in the PTB laboratory at the BESSY II synchrotron facility using 5.4 keV X-rays. An average transmission of approximately 61% was measured, with good spatial uniformity across the membrane area. Raster-scan measurements demonstrate a linear position response over ranges of ±500 µm and ±1 mm around the detector center, with position sensitivities exceeding 0.157 mm −1 and estimated upper-limit noise-equivalent positions of a few micrometres. Three-dimensional COMSOL simulations were used to model charge transport and lateral charge division in the real device geometry, showing excellent agreement with experimental results and confirming the independence of the position sensitivity from the beam spot size over a wide range of operating conditions. These results establish SiC rXBPMs as a compact, beam spot size calibration-free and radiation-hard solution for beam diagnostics at modern synchrotron light sources, with particular relevance for applications requiring large active areas, extended linearity and minimal beam perturbation.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Trovato et al. (2026) studied this question.

synapsesocial.com/papers/6a377f3a24f042ddf4c59ddahttps://doi.org/10.1107/s1600577526005242
Ask AI
Helpful
Bookmark
Share
View Full Paper