Key result
Balloon pulmonary valvuloplasty is associated with a ~35% reduction in RV pressure gradient in dogs.
Why the study?
What are the anaesthetic protocols, perioperative complications, and clinical outcomes of balloon pulmonary valvuloplasty in dogs with severe pulmonic stenosis?
Observational (n=21)
No
What are the anaesthetic protocols, perioperative complications, and clinical outcomes of balloon pulmonary valvuloplasty in dogs with severe pulmonic stenosis?
Balloon pulmonary valvuloplasty effectively reduces right ventricular pressure in dogs with severe pulmonic stenosis, though intraoperative hemodynamic instability and arrhythmias are common, requiring vigilant perioperative monitoring.
Answers are grounded in this paper and cite their sources.
BPV supports gradient reduction in canine pulmonic stenosis; observational data leave optimal anaesthetic and monitoring protocols open.
Introduction Balloon pulmonary valvuloplasty (BPV) is the most common interventional procedure for treating severe pulmonic stenosis (PS) in dogs. Due to the cardiovascular compromise associated with PS, anaesthetic management must be carefully planned to ensure patient safety. Objectives To describe the anaesthetic protocols, perioperative complications, and clinical outcomes of dogs with severe PS undergoing BPV. Methods A retrospective review of medical records was performed for 21 dogs with severe pulmonic stenosis (echocardiographic pressure gradient > 80 mmHg) that underwent balloon pulmonary valvuloplasty between 2024 and 2025. Anaesthetic protocols were individualized based on cardiovascular assessment. Data were analyzed descriptively, and statistical analyses were performed using IBM SPSS Statistics for Windows (version 25). A significance level of p < 0.05 was adopted. Results Twenty-one dogs were included, with a median age of 18 months (range: 3–84) and median body weight of 7.75 kg (range: 2.2–26). French Bulldogs were the most common breed (33.3%). Syncope (42.9%) and fatigue (38.1%) were the most frequent clinical signs. Anaesthetic induction was predominantly performed using etomidate–midazolam–based protocols (95%), and anaesthesia was maintained with mainly isoflurane combined with intravenous adjuncts. Hypotension (MAP < 65 mmHg) was the most common intraoperative complication, occurring in 66.7% of dogs, frequently requiring vasoactive support. Cardiac arrhythmias, including ventricular arrhythmias and bradyarrhythmia’s, were also observed. Balloon pulmonary valvuloplasty resulted in a significant reduction in right ventricular pressure gradient in 90% of cases. Conclusion Balloon pulmonary valvuloplasty effectively reduced right ventricular pressure in dogs with severe pulmonic stenosis. Anaesthetic management was heterogeneous, with frequent use of etomidate- and benzodiazepine-based induction and inhalant anaesthesia combined with intravenous adjuncts. Intraoperative hemodynamic instability and arrhythmias were common, reinforcing the need for individualized anaesthetic planning and vigilant perioperative monitoring.
No takes yet. Share an insight, caveat, or question.
Higa et al. (2026) conducted an observational in Severe pulmonic stenosis (n=21). Balloon pulmonary valvuloplasty vs. Pre-procedure baseline was evaluated on Right ventricular pressure gradient (mmHg) (Cohen's d 1.06, p=<0.001). Balloon pulmonary valvuloplasty significantly reduced the right ventricular pressure gradient from 109.26 mmHg to 70.5 mmHg in dogs with severe pulmonic stenosis.