Answers are grounded in this paper and cite their sources.
Compares alpha-particle track characteristics in GAGG and biological tissues, indicating vital insights for microdosimetry interpretation.
Objective. Real-time imaging of alpha-particle tracks in scintillators is promising for microdosimetric studies of alpha-emitting radionuclides in targeted radionuclide therapy. However, when inorganic scintillators such as Gd 3 Al 2 Ga 3 O 12 (GAGG) are used, the observed track characteristics differ from those in biological tissues. This study aimed to validate the GATE (geant4 application for tomographic emission) simulation framework using experimentally obtained alpha-particle track images and to compare track characteristics in GAGG and biological tissue-equivalent media. Such analysis is essential for quantitatively interpreting track images obtained with scintillator-based imaging systems in microdosimetry. Approach. Alpha-particle track images were obtained using a real-time high-resolution imaging system based on a GAGG scintillator and an Am-241 source. Simulated track ranges were compared with experimental images. The finalRange parameter in GATE was optimized because it affects the Bragg peak shape of alpha particles. Furthermore, simulated track characteristics in biological tissue-equivalent media were quantitatively compared with those in GAGG. Main Results. A bright endpoint artifact was identified in simulated alpha-particle tracks, originating from the particle transport mechanism implemented in Geant4/GATE and depending on the finalRange value. The simulated and experimental ranges of alpha particles in GAGG were 8.20 μ m and 8.05 μ m, respectively, demonstrating good agreement. Linear energy transfer (LET) values in GAGG were 2.8 and 1.8 times higher than those in adipose and bone, respectively. Significance. Recognizing this artifact is important for correct interpretation of LET distributions in microdosimetric evaluations. Our results demonstrated that GATE can accurately reproduce alpha-particle track characteristics and provides a useful framework for interpreting track structures observed in inorganic scintillators in terms of energy deposition in biological tissues. Nevertheless, optimization of the finalRange parameter is required for reliable microdosimetric evaluation.
No takes yet. Share an insight, caveat, or question.
Nakanishi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: