Key result
The proposed MP-DLNet-F model achieved 87.98% classification accuracy and an F1-score of 0.847 for detecting atrial fibrillation from variable-duration ECG signals on the CinC2017 database.
Why the study?
Typical CNN models for AF recognition from body surface ECG are not compatible with variable-duration ECG signals, limiting universality and clinical generalization.
A novel time-adaptive densely network (MP-DLNet-F) demonstrates high accuracy in detecting atrial fibrillation from variable-duration ECG signals, overcoming limitations of typical CNNs.
May facilitate AF detection from variable-length ECGs; leaves open prospective clinical validation.
Atrial fibrillation (AF) is one of the clinic's most common arrhythmias with high morbidity and mortality. Developing an intelligent auxiliary diagnostic model of AF based on a body surface electrocardiogram (ECG) is necessary. Convolutional neural network (CNN) is one of the most commonly used models for AF recognition. However, typical CNN is not compatible with variable-duration ECG, so it is hard to demonstrate its universality and generalization in practical applications. Hence, this paper proposes a novel Time-adaptive densely network named MP-DLNet-F. The MP-DLNet module solves the problem of incompatibility between variable-duration ECG and 1D-CNN. In addition, the feature enhancement module and data imbalance processing module are respectively used to enhance the perception of temporal-quality information and decrease the sensitivity to data imbalance. The experimental results indicate that the proposed MP-DLNet-F achieved 87.98% classification accuracy, and F1-score of 0.847 on the CinC2017 database for 10-second cropped/padded single-lead ECG fragments. Furthermore, we deploy transfer learning techniques to test heterogeneous datasets, and in the CPSC2018 12-lead dataset, the method improved the average accuracy and F1-score by 21.81% and 16.14%, respectively. Experimental results indicate that our method can update the constructed model's parameters and precisely forecast AF with different duration distributions and lead distributions. Combining these advantages, MP-DLNet-F can exemplify all kinds of varied-duration or imbalance medical signal processing problems such as Electroencephalogram (EEG) and Photoplethysmography (PPG).
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2022) studied Atrial fibrillation. MP-DLNet-F (Time-adaptive densely network) was evaluated on Classification accuracy for atrial fibrillation detection. The proposed MP-DLNet-F model achieved 87.98% classification accuracy and an F1-score of 0.847 for detecting atrial fibrillation from variable-duration ECG signals on the CinC2017 database.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: