Key result
Emergency clinicians demonstrated a pooled sensitivity of 88.6% and specificity of 81.6% for the visual assessment of TAPSE compared to reference standard M-mode measurement.
Why the study?
It was unknown whether emergency clinicians could accurately visually estimate RV function using TAPSE on point-of-care ultrasound clips compared to reference standard M-mode measurement.
Can emergency clinicians accurately visually estimate TAPSE on POCUS echocardiography compared to standard M-mode measurement?
Cross-Sectional (n=70)
No
Can emergency clinicians accurately visually estimate TAPSE on POCUS echocardiography compared to standard M-mode measurement?
Emergency clinicians demonstrated fair accuracy for the visual estimation of TAPSE on POCUS, suggesting it may be a feasible rapid assessment tool for right ventricular function in the emergency department.
Answers are grounded in this paper and cite their sources.
Supports visual TAPSE screening by ED clinicians; leaves open accuracy versus quantitative measurement in broader practice.
INTRODUCTION: Tricuspid annular plane systolic excursion (TAPSE) is an established echocardiographic marker of right ventricular (RV) systolic function. The objective of this study was to evaluate whether emergency clinicians can visually estimate RV function using TAPSE in a set of video clips compared to a reference standard M-mode measurement. METHODS: Emergency clinicians were shown a five-minute educational video on TAPSE. Participants then viewed 20 apical four-chamber point-of-care ultrasound (POCUS) echocardiography clips and recorded their estimate of TAPSE distance in centimeters (cm), as well as whether TAPSE was normal (>1.9 cm), borderline (1.5-1.9 cm), or abnormal (<1.5 cm). We calculated sensitivity, specificity, and overall accuracy of visual TAPSE categorization using M-mode measurement as the criterion standard. Participants also reported their comfort with assessing TAPSE on a five-point Likert scale before and after participation in the study. RESULTS: Among 70 emergency clinicians, including 20 postgraduate year 1-4 residents, 22 attending physicians, and 28 physician assistants (PA), the pooled sensitivity and specificity for visual assessment of TAPSE was 88.6% (95% confidence interval, 85.4-91.7%) and 81.6% (95% CI, 78.2-84.4%), respectively. The sensitivity and specificity for the clips in which the measured TAPSE was <1.5 cm or >1.9 cm was 91.4% (95% CI, 88.4-94.3%) and 90.8% (95% CI, 87.7-93.9%), respectively. There was no significant difference in sensitivity (p = 0.27) or specificity (p = 0.55) between resident and attending physicians or between physicians and PAs (p = 0.17 and p = 0.81). Median self-reported comfort with TAPSE assessment increased from 1 (interquartile range [IQR] 1-2) to 3 (IQR 3-4) points after participation in the study. CONCLUSION: A wide range of emergency clinicians demonstrated fair accuracy for visual estimation of TAPSE on previously recorded POCUS echocardiography video clips. These findings should be considered hypothesis generating and warrant validation in larger, prospective studies.
No takes yet. Share an insight, caveat, or question.
Duanmu et al. (2020) conducted a cross-sectional in Right ventricular systolic function assessment (n=70). Visual estimation of TAPSE vs. M-mode measurement (reference standard) was evaluated on Sensitivity of visual assessment of TAPSE (95% CI 85.4-91.7). Emergency clinicians demonstrated a pooled sensitivity of 88.6% and specificity of 81.6% for the visual assessment of TAPSE compared to reference standard M-mode measurement.
Synapse has enriched 10 related papers. Consider them for comparative context: