Answers are grounded in this paper and cite their sources.
Comparative analysis evaluates harmonic performance and dynamic response in NPC converters, highlighting the 5L-NPC's advantages.
This paper presents a comparative analysis of three-level (3L-NPC) and five-level (5L-NPC) Neutral-Point-Clamped converters using Finite Control Set Model Predictive Control (FCS-MPC) for reactive power compensation. The research addresses a critical gap by providing a direct performance comparison under identical operating conditions, supported by simulation and experimental validation of a 3L-NPC prototype. The study evaluates harmonic performance, dynamic response, and DC-link balance. Results demonstrate that the 5L-NPC topology significantly outperforms the 3L-NPC, achieving a simulated grid current Total Harmonic Distortion (THD) of 3.36% compared to 7.84% for the 3L-NPC. This 57.1% reduction in THD allows the 5L-NPC to comply with the IEEE Std. 519-2022 limit (<5%), whereas the 3L-NPC experimental results (9.9% THD) highlight the impact of practical non-idealities such as dead time and sensor noise. While the 5L-NPC offers superior power quality, it entails higher hardware complexity, evaluating 125 switching states compared to 27 in the 3L-NPC. These findings provide quantitative guidelines for selecting NPC topologies in high-performance grid compensation systems.
No takes yet. Share an insight, caveat, or question.
Paredes et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: