Demonstrates reliable damage localization and signal reconstruction under various temperatures.
In structural health monitoring, guided wave-based techniques are highly sensitive to environmental temperature, leading to spurious signal variations that obscure damage features and compromise localization accuracy. This article introduces a robust unsupervised and few-shot temperature compensation framework that achieves accurate signal reconstruction and reliable damage localization under diverse thermal conditions. The proposed approach requires only a limited number of baseline measurements, and avoids reliance on labeled damage data. First, a rolling pairing scheme is developed to expand training diversity from small datasets, enabling the model to learn cross-temperature relationships in an unsupervised manner. Second, four temperature-embedding operators are formulated to explicitly incorporate thermal information into the latent space. Finally, a channel-weighting mechanism adaptively emphasizes statistically reliable sensing paths while suppressing unstable ones. The framework is tested on a 9.2-m carbon steel pipe, achieving accurate signal reconstruction and stable damage localization under different temperatures and noise levels.
No takes yet. Share an insight, caveat, or question.
Ye et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: