Key result
Inter-operator MDCT discrepancies result in different hypothetical TAVI valve sizes in ~40% of low-risk patients.
Why the study?
Little is known about annular sizing imprecision and its impact on transcatheter aortic valve size in low-risk patients.
Does inter-operator variability in MDCT annular sizing impact TAVI valve size selection in low-risk patients with aortic stenosis?
Observational (n=50)
Blinded to each other and patient data
No
Does inter-operator variability in MDCT annular sizing impact TAVI valve size selection in low-risk patients with aortic stenosis?
Despite strong correlation in MDCT measurements among operators, inter-operator discrepancies lead to different TAVI valve size selection in 40% of low-risk aortic stenosis patients, highlighting a need for standardization.
Inter-operator MDCT variability may yield inconsistent TAVI sizing; leaves open standardization needs in prospective validation.
Aortic stenosis (AS), the most prevalent heart valve disease, is treatable through Surgical Aortic Valve Replacement (SAVR) or Transcatheter Aortic Valve Implementation (TAVI). Precise valve sizing is crucial for optimal clinical outcomes, minimizing risks like paravalvular leakage, conduction abnormalities, and patient-prosthesis mismatch. SAVR valve sizing is intraoperative, while Multidetector Computed Tomography (MDCT) measurements serve as the gold standard for TAVI sizing. The recent expansion of TAVI to low-risk patients reflects heightened confidence in its safety and efficacy. However, little is known about annular sizing imprecision in low-risk TAVR patients and its impact on valve size. This study aims to evaluate the inter- and intra-observer variability of MDCT-based measurements (annular area, perimeter, and diameter) and their impact on TAVI valve sizing. A secondary objective involves assessing intraoperative annular measurements against MDCT measurements. Fifty low-surgical-risk patients underwent SAVR. Preoperative MDCT, evaluated by three experienced cardiac MDCT operators, measured aortic annular parameters. Inter- and intra-observer variability were compared with intraoperative aortic valve sizers and predefined TAVI valve sizes. Among fifty low-risk patients with AS, strong correlation (Pearson > 0.90) was observed for all MDCT measurements between operators. However, interindividual differences led to diverse TAVI valve sizing in 40% of patients. No specific operator emerged as an outlier. Intraoperative annular diameter consistently measured smaller than MDCT-derived measurements. MDCT aortic annular measurements in AS patients exhibit strong correlation between operators. Yet, inter-operator discrepancies significantly impact TAVI valve sizing in a high percentage of patients, emphasizing the need for improved standardization.
No takes yet. Share an insight, caveat, or question.
Eerdekens et al. (2026) conducted an observational in Aortic stenosis (n=50). MDCT-based aortic annular measurements vs. Between operators / Intraoperative sizing was evaluated on Discrepant TAVI valve sizing between operators (Medtronic Evolut perimeter). Despite strong correlations in MDCT measurements between operators, inter-operator discrepancies resulted in different hypothetical TAVI valve sizes in up to 40% of low-risk patients with aortic stenosis.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: