Key result
Automated 3D TEE and MDCT led to the same TAVI prosthesis size selection in 88% of patients overall, with 95% agreement in those with low aortic valve calcium burden.
Why the study?
Does automated 3D TEE agree with MDCT for aortic annulus sizing and TAVI prosthesis selection in patients with severe aortic stenosis?
Observational (n=83)
Does automated 3D TEE agree with MDCT for aortic annulus sizing and TAVI prosthesis selection in patients with severe aortic stenosis?
Automated 3D TEE provides accurate aortic annulus sizing with excellent agreement with MDCT for TAVI prosthesis selection, especially in patients with low aortic valve calcium burden.
Answers are grounded in this paper and cite their sources.
Supports automated 3D TEE for TAVI sizing in low AVC burden; hypothesis-generating and requires prospective validation before practice change.
Accurate aortic annulus sizing is key for selection of appropriate transcatheter aortic valve implantation (TAVI) prosthesis size. The present study compared novel automated 3-dimensional (3D) transesophageal echocardiography (TEE) software and multidetector row computed tomography (MDCT) for aortic annulus sizing and investigated the influence of the quantity of aortic valve calcium (AVC) on the selection of TAVI prosthesis size. A total of 83 patients with severe aortic stenosis undergoing TAVI were evaluated. Maximal and minimal aortic annulus diameter, perimeter, and area were measured. AVC was assessed with computed tomography. The low and high AVC burden groups were defined according to the median AVC score. Overall, 3D TEE measurements slightly underestimated the aortic annulus dimensions as compared with MDCT (mean differences between maximum, minimum diameter, perimeter, and area: −1.7 mm, 0.5 mm, −2.7 mm, and −13 mm 2 , respectively). The agreement between 3D TEE and MDCT on aortic annulus dimensions was superior among patients with low AVC burden (<3,025 arbitrary units) compared with patients with high AVC burden (≥3,025 arbitrary units). The interobserver variability was excellent for both methods. 3D TEE and MDCT led to the same prosthesis size selection in 88%, 95%, and 81% of patients in the total population, the low, and the high AVC burden group, respectively. In conclusion, the novel automated 3D TEE imaging software allows accurate and highly reproducible measurements of the aortic annulus dimensions and shows excellent agreement with MDCT to determine the TAVI prosthesis size, particularly in patients with low AVC burden.
No takes yet. Share an insight, caveat, or question.
Podlesnikar et al. (2017) conducted an observational in Severe aortic stenosis (n=83). Automated 3-dimensional transesophageal echocardiography (3D TEE) vs. Multidetector row computed tomography (MDCT) was evaluated on Agreement on TAVI prosthesis size selection. Automated 3D TEE and MDCT led to the same TAVI prosthesis size selection in 88% of patients overall, with 95% agreement in those with low aortic valve calcium burden.